LIMIT CONDITIONS
Room temperature for
air conditioning 64 - 95°F (18° - 35°C)
Room temperature for
heating (on some models only) 50 - 77°F (10 - 25°C)
Maximum relative humidity : 80% RH
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
center appointed by the manufacturer only.
The appliance should be disposed of by a specialized
center appointed by your municipality.
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to en-
sure proper function. Without allowing the unit this time (6-24
hours) the unit may function for only a short time, and then the
compressor will break down from lack of oil.
ELECTRICAL CONNECTION
This appliance is equipped with a 3 prong grounded plug. The
plug must be connected into an outlet that is properly installed
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance.
If it will not t the outlet, have a proper outlet installed by a
qualied electrician or relocate the unit to a proper outlet. If the
household electrical supply does not meet the above specica-
tions, or if you are not sure your home has an eective electrical
ground, have a qualied electrician or your local electrical utility
company check it and correct any problems.
SAFETY PLUG
The appliance is tted with a safety plug to protect the power
cable. If power is cut o, unplug from the outlet and make sure
the power cable is undamaged. If the cable is damaged, call the
service center immediately. If power cuts o frequently and the
power cable is undamaged, contact a qualied electrician.
OPERATION OF THE SAFETY PLUG
If the safety device incorporated in the plug trips and cuts o
the power supply, check that the power cable and plug are not
damaged. If the power cable is undamaged, to restore operation
press the “RESET” button. To verify correct operation of the plug,
press the “TEST button periodically and make sure the appliance
disconnects. If this is not the case, contact the service center. To
restore operation, press the “RESET” button.