OPERATION
LIGHTING INSTRUCTIONS
Start-up Procedure
1. STOP! Read the safety information to the left on this label.
2. Open the lower access panel located below the replace screen.
3. Set the room thermostat, if present, to the lowest level. Set the wall
switch, if present, to its off position. Press slightly and turn the control
knob clockwise to the "OFF" position (See Fig. 1).
4. Wait ve (5) minutes to clear out any gas. Then smell for gas,
including near the oor. If you smell gas, STOP! Follow “B” in the safety
information to the left on this label. If you don’t smell gas, go to the next
step.
Note: LP gases do not vent upward.
Pilot ame ignition
5. Press slightly and rotate the "OFF / PILOT / ON" control knob
counterclockwise to the "PILOT" position.
6. With control knob depressed, push down on the ignition button until
the pilot lights. The pilot is located behind the replace screen, centered
near the rear of the burner.
Keep the knob fully depressed for at least thirty (30) seconds until air in
the pilot line vents and a strong pilot ame is present. Release the knob
and verify that the pilot ame remains lit. (See Fig. 2)
Millivolt
Generator
Pilot
Fig. 1 - Controls
Ignitor
• Do not attempt to light the pilot by hand.
Igniting the main burner
7. Conrm that the room thermostat or wall switch, if present, is set to its on position. Turn the "HI/LO"
knob to the "LO" setting.
8. Turn the control knob counterclockwise to the "ON" position. The gas path to the main burner is
now open. The maximum gas ow to the burner is obtained with the HI-LO knob fully turned counter-
clockwise ("HI" position). (See Fig. 1)
9. Close lower access panel.
• If the control knob does not pop up when released,stop and immediately call a qualied service
technician or gas supplier.
• If pilot goes out repeat steps 3 through 6. Wait (1) minute before attempting to light pilot again. If
after several tries the pilot still goes out, turn the gas control knob clockwise to the “OFF” position and
call a qualied service technician.
Stand-by position
10. To maintain a ame at the pilot burner with the main burner off, turn the control knob to the
"PILOT" position. (See Fig. 1)
Note: Pilot takes up to 1 min to ignite due to the time it takes the millivolt generator to heat up.
Fig. 2 - Pilot Flame
TO TURN OFF GAS TO APPLIANCE
1. Open the lower access panel located under the replace screen.
2. Turn control knob clockwise to the “OFF” position.
3. Close lower access panel.
Caution After shutting down, wait at least ve minutes before re-igniting. This will allow the safety
interlock to reset.