20
INSTALLATION
3. Screw all 6 standoffs into the studs of the wall.
WALL INSTALLATION
1. Adjust the standoffs to the wall thickness.
2. Carefully lift the insert through the center
opening in the front of the wall. Slide the insert
back through the opening until the metal trim
makes contact with the front of the wall.
1
2
THE FINAL DIMENSION OF THE FIREPLACE INSTALLATION
THE DISTANCE BETWEEN DRYWALL AND THE EDGE OF
FIRE PLACE CHAMBER IS AT LEAST 0.57 INCH
XSEC0001-XSEC0001SECTION
9/16”