COMMISSIONING
79
OUTLET TEMPERATURE COMPENSATION ADJUSTMENT 876 SERIES
The maximum outlet temperature of an 876 series 612 to 620 and E16 model water heater may be adjusted
to compensate for temperature losses in the pipe work between the water heater outlet and sanitary fixtures.
Warnings
After adjustment, the water temperature from the first tap in the hot water pipe work after the water
heater used for personal hygiene purposes, such as in a bathroom or ensuite, MUST NOT exceed:
48°C if a temperature controller is connected to the water heater, or
50°C if a temperature controller is not connected to the water heater.
If there is a tap, such as a kitchen or laundry tap, in the hot water pipe work between the water heater
and the first tap used for personal hygiene purposes, then it is possible for a water temperature to be
delivered from that tap of up to 3°C to 5°C higher than the setting shown on the controller.
It is necessary to have the electrical supply to the water heater switched on during stages of the outlet
temperature compensation adjustment procedure.
Warnings
The removal of the front panel will expose 240 volt wiring. Take care not to touch wiring terminals. The
adjustment must be carried out by a qualified person.
This procedure will involve the adjustment of dip switches. Adjustment of a dip switch should only be
made with an insulated tool.
Before Commencing the Procedure
This procedure cannot be conducted:
With a temperature controller connected to the water heater.
A temperature controller(s) connected to the water heater must be disconnected prior to the
commencement of this procedure. Refer to
“Disconnecting a Temperature Controller(s)” on
page 79.
With an Ez-Link system set up on the water heaters.
The DIP SWITCHES need to be reset to the off (down) position on both water heaters prior to the
commencement of this procedure.
The Ez-Link cable does not need to be disconnected.
The Outlet Temperature Compensation Adjustment
procedure has to be performed individually on both
water heaters.
Whilst the procedure is being conducted on one water
heater, the other water heater has to be isolated by
turning off the cold water isolation valve to the water
heater.
Disconnecting a Temperature Controller(s)
To disconnect the temperature controller(s):
1. Switch off the electrical supply at the power outlet to the
water heater.
2. Unscrew and gently remove the front panel of the water
heater.
3. Loosen the terminal screws to release the cable lugs.
The two remote controller terminals are adjacent to each
other and located at the top right of the printed circuit board
(PCB), to the right of the label marked ‘REMOTE
CONTROLLER TERMINAL’.
4. Withdraw the cable lugs, ensuring they are well clear of the
terminals.