Richmond 10E50-HP530 Wi-Fi 50 Gallon Electric Water Heater

Use & Care Manual - Page 15

For 10E50-HP530.

PDF File Manual, 40 pages, Read Online | Download pdf file

10E50-HP530 photo
Loading ...
Loading ...
Loading ...
15
HVAC approved ducting.
Calculated length of duct no greater than
maximum allowed.
UL Certified terminations (For ducting to the
outside).
Insulated duct.
Ducting adequately supported.
Ducting adequately isolated from structure.
Make sure valve is open condition .
Make sure sensor is dry and doesn't touch the
water during installation.
Installation Checklist
A. Water Heater Location
Close to area of heated water demand.
Indoors and protected from moisture, wet
conditions, freezing temperatures (below 32°F
(0°C)) and High temperatures (above 140°F
(60°C)).
Area free of flammable vapors.
Provisions for Air Circulation (Louvered doors on
ducting).
Provisions made to protect area from water damage.
Sufficient room to service heater.
Six inches (6") of clearance from ceiling to
top of Hybrid Water Heater to allow for filter
maintenance.
Access to condensate disposal.
Vibration Isolation Kit (Non-Concrete floors).
Hybrid seismic Kit (if required).
B. Water Supply
F. Ducting
G. Shutoff Valve
H. Leak Sensor
Water heater completely filled with water.
Air purged from water heater and piping.
Water connections tight and free of leaks.
Flexible water connections.
C. Relief Valve
Temperature and Pressure Relief Valve properly
installed and discharge line run to open drain.
Discharge line protected from freezing.
D. Wiring
Power Supply voltage agrees with water heater
rating plate.
Branch circuit wire and fusing or circuit breaker
of proper size. (Recommended 15 amp & 30 amp
breaker for select models).
Electrical connections tight and unit properly
grounded.
10 gauge wire.
E. Condensate Lines
Condensate lines from heat pump installed
correctly.
Condensate lines from heat pump run to a
suitable drain location.