Technical data
38 PW 811 / PW 814 / PW 818
Water connection
Models with detergent dispenser drawer (WEK)
Permitted supply pressure 14.5-145 psi (1-10 bar)
Maximum intake rate 21 gal/min (79.5 l/min)
Cold water connection
(to be provided on site, external thread according to DIN 44991, flat seal)
2 x ¾"
Optional cold-hard water connection
(to be provided on site, external thread according to DIN 44991, flat seal)
2 x ¾"
Hot water connection≤158°F(70°C)
(to be provided on site, external thread according to DIN 44991, flat seal)
1 x ¾" (25 x 19 mm)
Intake hose length 59" (1500 mm)
Drain valve
Maximum drain water temperature 203°F (95°C)
Waste water connection (on machine) NPS 2 ¾" (DN 70) plastic pipe
Drain (on-site) 2 ¾" connection
Maximum drainage rate 53 gal/min (200 l/min)
Optional steam valves for steam-heated models
Electric steam valve (ELD01)
Regulatable steam pressure 29 - 145 psi (200 - 1000 kPa)
Connection size 1/2" (12 mm)
Connection voltage 1N AC 230V
Frequency 50-60Hz
Pneumatic steam valve (PND)
Regulatable steam pressure 0 - 145 psi (0 - 1000 kPa)
Connection size 1/2" (12 mm)
Connection for equipotential bonding
Connection with male thread (machine) 3/8" x 1 3/8" (10 x 35 mm)
Washers and nuts M10