Forno FFSGS626048 48 Inch Stainless Steel Gas Freestanding Range, in Stainless Steel

User Manual - Page 13

For FFSGS626048.

PDF File Manual, 30 pages, Download pdf file

Loading ...
Loading ...
Loading ...
13
a 
Installation must comply with local codes or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 / NFPA 54. In Canada, installation must conform to the current natural
Gas Installation /code, CAN 1-1.1-M81 and with local codes where applicable.
This range has been design-certified according to ANSI Z21.1b-2012 latest edition.
GAS REQUIREMENTS
NATURAL GAS
WC
Supply Pressure 5" (12.5 mb)
Minimum Supply Pressure
6"
Max Regulator Pressure
14" (34.9 mb), 0.5 psi (3.5 kPa)
LP GAS
WC
10" (25 mb)
11"
14" (34.9 mb), 0.5 psi (3.5 kPa)
Ventilation: it is recommended that the unit be operated with an oven head, vented exhaust
hood of sufficient size and capacity.
Electric Power Supply Requirements
Supply Pressure
Minimum Supply Pressure
Max Regulator Pressure