Loading ...
Loading ...
Loading ...
Solutions To Common Problems
Ice Dispenser
Cause
Water supply is not connected.
Ice storage container is empty.
Freezer temperature is set too warm.
Householdwater line valveis not
open.
Freezerdoor is not closed.
Icedispensingarm hasbeen heldin
formore than 4-5minutes.
Problem
Dispenser will not
dispense ice.
Correction
Connect water supply (see page 9).
When the first supply of ice is dropped into the container,
the dispenser should operate.
Turn freezer control to a higher setting so that ice cubes
will be made. When first supply of ice is made, dispenser
should operate.
Open household water line valve. Allow suff+cient time for
the ice to be made. When ice is made, the dispenser
should operate.
Ensure freezer door is closed.
Motor is overloaded. Motor overload ptz)tector will reset in
approximately 3 minutes. Ice can then be dispensed.
Ice dispenseris
jammed.
Ice has melted and frozen atT)und
auger due to infrequent use,
temperature fluctuations, and/or
power outages.
Ice cubes are jammed between ice
maker and back of ice container.
Ice cubes are frozen together.
Icecubes arehollow or smallerthan
normal.
Remove ice container,thaw, andemptythe contents.
Cleancontainer,wipedry, and replacein proper position.
Whennew ice is made,dispensershouldoperate.
Remove ice cubes that are jamming the dispenser.
Use the dispenseroften sothat cubesdo not freeze
together.
The ice & water filtercartridgecould be clogged.Replace
the filtercartridge.Dispensingsystemoperatesbest at 30-
100psi water pressure.Wellwater pressuresshouldfall
within this range.
Water Dispenser
Problem Cause Correction
Dispenserwill not
dispensewater.
Water supply is not connected.
Household water line valve is not
open.
Freezer door is not closed.
Ice & water filter cartridge is clogged.
Front filter not fully installed, if
equipped
Connectwatersupply(see page9).
Open householdwaterline valve.See Problemsection Ice
Maker tsNot MakingIce.
Ensure that freezerdooris closed.
Replacefiltercartridge.
Push filterin until you heara "click".Filter shouldbe flush
with cabinet.
Water has an odd
taste and/or odor.
Waterhas beenin the tank for a
periodof time.
Unitnot properlyconnectedto cold
water line.
Tubingused in the householdwater
supplyand installationmay affect
watertaste and odor.
Waterhas a high mineral content.
Drawand discard10-12glassesof water to freshenthe
supplyand completelyrinse out the tank.
Connect unit to cold waterline that supplieswater to the
kitchenfaucet.
For bestresults,usecoppertubing for water connections.
Contact water treatment plant for help.
Water pressure is
extremely low.
Cut-off andcut-onpressuresaretoo
low (wellsystemsonly).
Reverseosmosissystemis in
regenerativephase.
Havesomeoneturn up the cut-offand cut-onpressureon
the water pumpsystem (wellsystemsonly).
tt is normalfor a reverse osmosissystemto be below20
psi duringthe regenerativephase.
Loading ...