Rinnai ORH18MR 1800w Outdoor Radiant Heater

User Manual - Page 10

For ORH18MR.

PDF File Manual, 20 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Rinnai 10 ORH OIM
REGULATORY REQUIREMENTS
The heater must be installed in accordance with the manufacturers installation instructions.
The heater MUST ONLY be installed or removed by an authorised person.
The heater MUSTbe installed in accordance with AS/NZS 3000 and all other applicable local municipal 
building codes including OH&S requirements
UNPACKING
IMPORTANT
If any damage is present DO NOT INSTALL or OPERATE the appliance and contact your supplier
for advice.
APPROXIMATE HEATING AREA
A
B
C
Heater
Indoor Area Spot Heating
Dimension ORH15SR ORH18MR ORH24LR ORH32XLR
A 1030 1210 1490 1900
B 1700 2050 2650 3550
C 2150 2150 2150 2150
Outdoor Covered / Enclosed Area
Dimension ORH15SR ORH18MR ORH24LR ORH32XLR
A 1030 1210 1490 1900
B 1400 1600 2050 2750
C 2150 2150 2150 2150
OUTDOOR RADIANT HEATER MOUNTING
This outdoor radiant heater comes with a pair of stainless steel adjustable angle mounting brackets. The adjustable 
angle enables the heater to be installed on vertical, horizontal and inclined surfaces.
The  ideal  mounting  position  is  directly  above  the  area  to  be  heated  with  a  longitudinal  orientation  and  facing 
vertically downwards. If this is not possible, the heater(s) can be mounted on a wall and angled downwards. For 
this application ensure the mounting height is within 2.1m to 2.7m.
WARNING
The heater must never be installed in the upwards or inwards facing position, the heating surface
must always be positioned to direct the heat in a downwards or outwards direction.
Vertical wall mount
Inclined ceiling mount
Horizontal ceiling mount
Angled horizontal ceiling mount
Correct Installation
Incorrect Installation
WALL
WALL
WALL
WALL
CEILINGCEILINGCEILINGCEILING
INSTALLATION
Loading ...
Loading ...
Loading ...