TROUBLESHOOTING
8
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Motor does not run 1. Machine not plugged in 1. Plug power cord into electrical receptacle
2. ON/SPEED button is in "OFF" position 2. Press the ON/SPEED button to turn unit on
3. Power switch or cord is faulty 3. Replace switch or power cord
4. Blown fuse 4. Overloaded electrical circuit
5. Remote control is not working 5. Point remote control directly at control panel
- Make sure remote sensor on the control panel is not
blocked
- Move remote control closer to the control panel for better
direct signal
6. Remote control batteries are dead 6. Replace batteries. See Remote Control Battery
Replacement for instruction
7. Receiver is not working 7. Inspect or replace control panel circuit board
8. Control panel ON/OFF button is not working 8. Inspect or replace control panel circuit board
9. Motor does not work 9. Replace motor
Motor stalls or
does not have full
power
1. Incorrect line voltage 1. Have a qualified electrician check circuit for proper voltage
2. Motor capacitor has failed 2. Replace motor capacitor
3. Control panel circuit board has failed 3. Inspect or replace control panel circuit board
System has
vibration or is
noisy
1. Motor or cabinet part is loose. 1. Inspect all hardware and retighten or replace
2. Motor fan is rubbing cover 2. Check position of fan and cover. Adjust or replace loose/
damaged part
3. Motor bearings are loud 3. Rotate motor shaft to isolate the issue. Replace worn
bearings
4. Air filters rattle 4. Inspect and reposition filters
5. Impeller fan is loose, unbalanced or
damaged
5. Turn machine off and unplug from power
- Inspect impeller for bent or damaged areas
- Secure impeller on motor shaft and replace if any
damage is found
6. Motor base is loose in the cabinet 6. Tighten any loose fasteners
Poor air flow and
dust collection
1. Filters are dirty 1. Clean or replace both air filters frequently. See Change
Filters for instruction
2. Poor system location in shop 2. Reposition system in the shop for best air circulation
Fuse blows 1. Wrong fuse 1. Replace with correct fuse
2. Undersized or excessive length of
extension cord
2. Use correct size extension cord