AGA AHCCLT 20 Inch Freestanding Electric Range with 1 Warmin

User Manual - Page 19

For AHCCLT.

PDF File Manual, 28 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Hotcupboard
plinth base
3/8” (11mm) height
dierential
Fig. 6.7
Fig. 6.8
15
2. Position the plinth alongside the AGA Total
Control / Dual Control leaving no gap between the two
plinths (see Fig. 6.7).
3. Attach hotcupboard plinth to the AGA Total
Control / Dual Control plinth using M6 screws and
washers provided (See Fig. 6.8).
Check with a spirit level that the plinth level is correct, and
also check height dierential between the hotcupboard
plinth and Total Control / Dual Control plinth is correct 3/8”
(11mm).
If necessary, use shims in each corner to level the plinth.
Attach locking screw and jacking screw into plinth. Make sure
at this stage that the jacking screw does not protrude beyond
outer face of plinth. Ensure locking screw is located into AGA
Total Control / Dual Control plinth but not fully tightened.
A gap of approximately
1
/8 (3mm) should be present
between the plinths apart from at the very front where the
hotcupboard spacer plate should be touching the AGA Total
Control / Dual Control plinth.