Hestan KICS30MS 30 Inch Electric Smoothtop Cooktop

User Manual - Page 11

For KICS30MS.

PDF File Manual, 28 pages, Read Online | Download pdf file

KICS30MS photo
Loading ...
Loading ...
Loading ...
©2019 Hestan Commercial Corporation
9
EN
Disconnect power before servicing the product. Failure to do so could result in death or
electrical shock.
Your cooktop can use 200-240V at 50 or 60 Hz.
The connection leads are 3x8 AWG copper.
This cooktop does not require a neutral connection. If the cooktop is to be completely enclosed
in a cabinet, feed the cooktop cable through the opening in the cabinet.
Make the electrical connection following the appropriate steps for your installation.
The 3/4” flexible conduit is 4-1/2 feet long [1.37 m] located at the right rear of the cooktop
housing. Do not cut the conduit. It should be connected directly into a junction box with a U.L -
or CSA - listed conduit connector.
A dedicated time-delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the grounding circuit.
Both supply (phase) lines must be protected by fuses or a circuit breaker.
A three-wire, single-phase, 200-240 V, 60 Hz electrical system (properly circuit protected to meet
local codes of NFPA No.70 must be provided. The unit must be properly grounded in accordance
with local wiring codes. The chart on page2 recommends the minimum circuit protector size
if the appliance is the only unit on the circuit.
If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be
created. It is advisable that the electrical wiring and hookup be accomplished by a competent
electrician.
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts
02169-7471
USA
COOKTOP INSTALLATION
(CONT.)
COOKTOP INSTALLATION OVER A SINGLE OVEN
Use the countertop opening dimensions that are given with these instructions.
The cooktop may be installed over a single oven. The oven must exhaust out of the cooktop
enclosure.
The cooktop should be centered over the oven.
The cooktop and the oven must be installed according to each specific installation instruction.
B
A
JUNCTION BOX LOCATION
The ELECTRICAL CONDUIT is 4-1/2 feet
[1.37 m] long. DO NOT CUT THIS CONDUIT.
The junction box must be located where it
will allow considerable slack in the conduit for
serviceability.
A) Place junction box so that the conduit
will easily reach it. Make sure that the
conduit will clear any drawers or other
obstructions.
B) Install junction box so that it can be
reached through the front of the cabinet.
ELECTRICAL CONNECTIONS
Figure 9. Location of electrical connection
Loading ...
Loading ...
Loading ...