Vert-I-Pak Installation Recommendations
Forproperunitperformanceandmaximumoperatinglifepleaserefertothe minimuminstallationclearancesbelow.
Figure I
VERT-I-PAK ® units must be installed on an outside wall. Confined spaces and/or covered areas should be
avoided. Units should be installed no closer than 12" apart when two units are side by side. If three of more
units are to operate next to one another allow a minimum of 60" between units or pairs of units. Also, a vertical
clearance of 60" should be maintained between units. Units installed on the bottom floor should be mounted
at least 6" off of the ground.
_A_
SMALL RECESS OK 60" 60"
LARGER RECESS OK IF A> 5xB
\
D
6" 7_
60" E
60" E
J
6" 3
D D D
D D
D D
D D D
D
D
D
60'_
H
12"
Figure2
Any time obstructions are present use
the following guidelines for proper
spacing from the VERT-I-PAK louver:
For minor obstructions such as lamp
poles or small shrubbery a clearance
of 24" from the outdoor louver should
be maintained.
For major obstructions such as a solid
fence, wall or other heat rejecting
device like a condensing unit, a mini-
mum distance of 72" should be kept.
BUILDING
OUTDOOR "72"
UNIT
FENCE
MAJOR OBSTRUCTION
The above suggestions are for reference only and do notrepresent allpossible installations. Please contact the factory
for information regarding affects of other installation arrangements.