Installation instructions
EXHAUST CONNECTION
_WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
This dryer must be exhausted outdoors.
Use only metal duct.
Do not terminate _'xhaust in a chimney, any gas vent,
under an enclosed floor (crawl space), or into an attic.
The accumulated lint could create a fire hazard.
- Provide an access for inspection and cleaning of the
exhaust system, especially at turns. Inspect and clean at
least once a year,
o Never terminate the exhaust into a common duct with a
kitchen exhaust. A combination of lint and grease could
create a fire hazard.
Do not obstruct incoming or exhausted air.
THiS DRYER COMES READY FOR REAR
EXHAUSTING. iF SPACE iS LIMITED, USE
THE iNSTRUCTIONS iN SECTION 9 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
STANDARD REAR EXHAUST
(Vented at floor level)
FORSTRAIGHT
LINEiNSTALLATiON,
CONNECTTHE
DRYEREXHAUST
TOTHEEXTERNAL
EXHAUSTHOODUSING
DUCTTAPEORCLAMP.
--: (CORDNOTSUPPLIED
:"" WITHDRYER)
CUTTHEMETALEXHAUST
DUCT(NOTSUPPLIED)TOTHE
PROPERLENGTH.
NOTE:WESTRONGLYRECOMMENDSOLIDMETALEXHAUSTDUCTING.
HOWEVER,IFFLEXIBLEDUCTINGISUSEDITMUSTBEMETALNOTPLASTIC.
STANDARD REAR EXHAUST
{Vented above floor level)
ELBOWHIGHLY
RECOMMENDED
ELBOWHIGHLY
RECOMMENDED
RECOMMENDED
CONFIGURATION
TOMINIMIZE
EXHAUST
BLOCKAGE.
NOTE: ELBOWS WiLL PREVENT DUCT
KiNKiNG AND COLLAPSING.
[_ LEVELING AND STABiLiZiNG
YOUR DRYER
STANDTHEDRYERUPRIGHTNEARTHEFINALLOCATIONANDADJUST
THE4LEVELINGLEGS,ATTHECORNERS,TOENSURETHATTHEDRYER
iSLEVELFROMSiDETOSIDEANDFRONTTOREAR.
LEVEL
FRONT-TO-BACK. LEVEL
"_ SIDE-TO-SiDE.
4LEVELING
LEGS