Kenmore 58071082100 air conditioner

User Manual - Page 5

For 58071082100.

PDF File Manual, 25 pages, Download pdf file

Loading ...
Loading ...
Loading ...
INSTALLATION REQUIREMENTS
Your air conditioner will install into standard double
hung windows with actual clear opening widths of
22 to 36 inches (559mm to 915mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 15 inches (381mm). Side louvers
and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
_._ _ Sash
-1-22" to 36"--
1 II .
5=mm. Inner sill _ Window
- O,se,
l s,,
Intedor wall "
FIG. 1
ELECTRICAL SERVICE
Check youravailable electricalservice.The power
supply available mustbe thesame as thatshown
on the unitnameplate(foundonrightsideofcabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton is the best way to store
unit during winter or when not in use.
INSTALLATION HARDWARE
ITEM NAME OF PARTS
A SIDE CURTAIN
B SILL SUPPORT
C BOLT
D LOCK NUT
E SCREW: 25/64"
F SCREW: 5/8"
G SCREW: 5/8"
H FOAM SEAL
I FOAM STRIP
J L BRACKET
REQUIRED TOOLS:
FIG. 2 i
Q'TY
2
2
2
2
13
3
5
1
1
1
To avoid risk of personal injury, propertydamage,
or product damage due to the weightofthis
device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an
excesswe weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper liftingand
carrying techniques when moving unit.
Carefully inspect location where air conditioner
will be installed. Be sure itwillsupport the
weight of the unit over an extended perior of
time.
Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
Make sure air conditioner does notfall during
installation.
Tight Fitting gloves
Standard screwdriver
Phillips screwdriver
Pliers
Sharp knife
3/8-inch open end wrench or adjustabte wrench
1/4-inch hex socket and ratcher
Tape measure
Electric drill
1/4-inch drill bit