16 Installation & Operation Manual Copyright © Puretec Pty Ltd 2018
Cartridge Performance Data
Performance Data
Substance Guidelines*
Average
Concentration
Concentration
Min Percent
Removal
Average
Concentration
Average
Percent
Removal
NSF Standard 42 Drinking Water Treatment Units
Chlorine
(23,000 L)
2.1 0.3 50% 0.25 >94%
Standard 53 Cyst Live Cryptosporidium POU/POE
Cyst <1 100,000 ND (1) 99.98% + ND (1) 99.99%
Test Parameters
Hardness, Total mg/L 120
TDS mg/L 290
Temp deg C 21°C
Turbidity NTU 0.1
pH 7.57
ND = Not Detected
This appliance meets the domestic water treatment appliance Standards AS/NZS3497 for the following
water treatment processes:
Class Treatment type Function Pass
I Microbiological Status
Bacteriostatic Will stop bacteria increasing, but will not
remove them unless II(a) is passed.
N/A
II Microbiological Treatment
II (a) Bacteria Removal Will remove or inactivate bacteria.
II (b) Virus Removal Will remove or inactivate virus.
II (c) Protozoa Removal Will remove or inactivate Cryptosporidium
and Giardia, but will not remove or
inactivate bacteria and virises unless II(a)
and II(b) is passed.
III Turbidity & Particulate Reduction Reduces cloudiness.
IV Taste & Odour Reduction Reduces taste & odours.
V Chemical Treatment Decreases chlorine.