INSTALLATION REQUIREMENTS
Installation must be performed by a qualifi ed professional service
technician.
This grill is designed for outdoor use only. DO NOT use this grill inside
a building, garage, enclosed area, or under an unprotected overhead
combustible construction.
See below and the EXHAUST REMOVAL section on the following
page for details on installing under overhead construction.
DO NOT use this grill in or on a recreational vehicle or boat.
Important: If installing this grill in a combustible surround, the correct
AOG insulating liner must be used.
Important: Refer to the information below to ensure all required
clearances are met.
The grill must have a minimum clearance of 18" from combustible
materials/items AT ALL TIMES.
Overhead Construction Requirements (if applicable)
Non-combustible overhead construction: A 6 foot clearance is required
between the countertop and the construction above (Fig. 10-1).
Combustible overhead construction: A 6 foot clearance is required
between the countertop and the construction above. A vent hood (see
EXHAUST REMOVAL section) or an AOG combustible overhead
protection kit is required directly above the grill. See Fig. 10-1. Vent
hoods and protection kits are available, contact your local dealer.
Side and Rear Wall Clearances
For the minimum clearances between the grill and any side or rear
walls, your setup must fall within one (or more) of the following:
A. Clearance between grill and strictly non-combustible wall
(i.e. brick wall, see Fig. 10-2)
The grill must have a minimum of 4" right, left, and rear
clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)
B. Clearance between grill and a protected combustible wall
(i.e. a non-combustible wall in front of a combustible wall to serve
as a barrier. This can be accomplished by brick, or a metal stud
nished with non-combustible substrate, see Fig. 10-3)
The grill must have a minimum of 14" right, left, and rear
clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10"
clearance between the grill and protected wall.)
C. Clearance between grill and combustible wall
The grill must have a minimum of 18" right, left, and rear
clearance from any combustible wall (see Fig. 10-4).
Backsplash Clearance (if applicable)
If a non-combustible backsplash exists, it must have a minimum of a
4" clearance from the rear of the grill (to allow for proper ventilation
and prevent dangerous overheating). See Fig. 10-5.
Important: This 4" backsplash clearance must fi rst be met prior to
any non-combustible walls beginning behind it.
Fig. 10-2 Clearance 'A' Diagram
Fig. 10-3 Clearance 'B' Diagram
Fig. 10-4 Clearance 'C' Diagram
Non-combustible
Min.
4"
Min.
14"
Non-combustible
substrate
Non-combustible 4"
Combustible
Min.
18"
(Clearance required for
right, left, and rear)
Fig. 10-5 Backsplash clearance
Non-combustible
Backsplash
Min.
4"
Com-
bustible
(Clearance required for
right, left, and rear)
(Clearance required for
right, left, and rear)
Fig. 10-1 Overhead requirements
Min.
6'
Combustible construction:
Requires vent hood or protection kit
Non-combustible construction:
Okay as-is
REV 0 - 1412011330