User Manual Viking RDLPKR3 LP/Propane Conversion Kit

Documents for Viking RDLPKR3

The following documents are available:
User Manual Photos
RDLPKR3 photo
The pressure regulator and the burner orifices are set for Natural
gas. To use Liquid Propane gas, the regulator and burner orifices
must be converted.
To convert the range to LP gas, follow these instructions:
1. Disconnect all electrical power at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1. Locate the pressure regulator which can be found on the back
of the range on the right hand side if facing the back of the
range.
2. Unscrew the hex nut cap from the top of the regulator.
3. Unsnap the plastic plunger from the hex nut.
4. Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note: Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.
Converting the Surface Burners
1. Remove the top grates, burner caps, and burner heads.
2. Using a 9/32” or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note: Save these orifices for future conversion back to Natural gas,
if required.
3. Locate the proper LP surface
burner orifices included with
the kit according to the chart
below.
4. Install the orifices in their
correct location. To prevent leakage, make sure the orifice
spuds are securely screwed into the burner base.
WARNING
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow ALL instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
NAT
LP
NAT
LP
Apply sideways finger pressure
to remove pin from cap.
NAT
LP
conversion
conversion
Orifice
spud
Burner
cap
Burner
grate
Burner
head
Burner
base
Orifice
size
0.79
Orifice
Burner BTU Rate
Orifice Size
Left front (dual)
High
Low
15,800
1,000
1.09
0.33
Left rear
6,500 0.79
Center 8,000 0.87
Right front 15,000 1.19
Right rear 11,000 1.01
Bake 30,000 1.68
Broil 14,500 1.03
RDLPKR3 LP Conversion Kit Instructions
for D3/3 Series Gas Self Clean and Dual Fuel Range
0.79
1.09
0.33
1.19
0.87 1.01
Burner BTU Rate
Orifice Size
Left front
15,800
1.19
Left rear
6,500 0.79
Center 8,000 0.87
Right front 15,000 1.19
Right rear 11,000 1.01
Bake 30,000 1.68
Broil 14,500 1.03
0.79
1.19 1.19
0.87 1.01
D3