SANTOS: User and maintenance manual
98155 EN 4.3- 05 2018 12/ 22 www.santos.fr
The 2 selector buttons are set independently (fig. D).
Generally speaking:
The 2 "+" and "-" buttons (22) are used to increase or decrease the values and
the "Selection" buttons (20 and 21) are used to confirm the timer values.
Pressing simultaneously on both the "+" and "-" buttons (22) for 2 seconds activates the
"timer setting" mode".
"1 XXX" appears on the screen (timer 1 value) and the "1 coffee" button (20) flashes
(indicating setting of the value of the 1 coffee timer)
o pressing the "+" button increases the value by one unit
o pressing the "-" button decreases the value by one unit
o pressing either of the 2 "Selection" buttons confirms the value displayed and
gives access to setting of the timer "2". The value of the timer "2" appears.
"2 XXX" appears on the screen (timer 2 value) and the "2 coffee" button (21) flashes
(indicating setting of the value of the 2 coffees timer).
o pressing the button "+" increases the value by one unit
o pressing the button "-" decreases the value by one unit
pressing either of the 2 "Selection" buttons confirms the value displayed, saves it and
returns the machine to the normal operating mode.
Timer setting range
No. 1 "1 coffee": from 40 to 499
No. 2 "2 coffees": from 80 to 999
The machine is set in the factory. You can initialise the factory parameters at any time.
Initialising the factory parameters
1. Turn the machine off (On / Off switch (11) to the (0) position)
2. With one hand, press and hold down both the "+" and "-" adjustment buttons and
then at the same time turn the power on (On / Off switch (11) to the (1) position). A
test procedure is launched at the end of which the factory parameters are
reinitialised.
If you release either of the buttons during the test phase, the initialisation is cancelled
and your settings retained.