Mastech MS5202 High Voltage Insulation Tester

OPERATOR’S MANUAL - Page 24

For MS5202.

PDF File Manual, 26 pages, Read Online | Download pdf file

MS5202 photo
Loading ...
Loading ...
Loading ...
DIGITAL + ANALOGUE HIGH VOLTAGE INSULATION TESTER
OPERATOR’S MANUAL
MAINTENANCE
because of its leakage.
Replacing all of the old battery with new one, never intermix them.
Had better use the Alkaline battery
5.1.2 9V6F22BATTERY REPLACEMENT
5.1.2.1 If the sign appears on the LCD display, it indicates that the battery should be replaced.
5.1.2.2 Loosen the screw fixing the battery cover and remove it.
5.1.2.3 Replace the exhausted battery with a new one.
5.1.2.4 Put the battery cover as its origin.
5.2 TEST LINE AND TEST CLIPS REPLACEMENT
WARNING
Full in compliance with safety standards can be guaranteed only if used with test line or test
clips supplied. If necessary, they must be replaced with the same model or same electric ratings.
Electric ratings of the test line or test clips: 2500V 1A
You must replace the test line or test clips if the lead is exposed.
- 21 -
Loading ...