Elica EMD530S2 Aspire Series 30 Inch Stainless Steel Convertible Chimney Style Under Cabinet Hood

User Manual - Page 9

For EMD530S2.

PDF File Manual, 52 pages, Read Online | Download pdf file

EMD530S2 photo
Loading ...
Loading ...
Loading ...
9
Outside rear exhaust
(Horizontal duct– 3 1/4”x 10” Rectangular)
• Use the diagram or the hood as a template and mark the
locations on the cabinet for ductwork, electrical wiring and
keyhole screw slots.
Installation to wall
(Horizontal duct– 3 1/4”x 10” Rectangular)
• Use the diagram or the hood as a template and mark
the locations on the wall for ductwork, electrical wiring
and keyhole screw slots.
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2
wood shims the width of the trim and attach them to
the cabinet bottom recess on both sides.
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4” extra toward
the front of the cabinet so you can move the duct
freely when installing the hood.
It may also ease installation by cutting the hole 10 1/2”
instead of 10”.
Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.
Fix the wiring conduit to the hood.
Slide the hood back against the wall. Tighten the
mounting screws. Be sure the screw heads are in the
narrow neck of the keyhole slot.
Connect Ductwork to hood.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction
box.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
Final installation step
Replace
the 2 lateral supports.
Replace filters.
Check operation of the hood.
Loading ...