hose or regulator failure, or a leak. If it is evident that the flow-limiting device has
activated, the cause of the excessive flow should be determined and corrected before
using your grill/side burner again.
Improper lighting procedures can also cause the flow-limiting device to activate,
resulting in reduced heat output. If this is suspected, shut off all burner controls and
cylinder valve, and carefully repeat lighting instructions step by step. Do not remove
the nut and probe and do not attempt to connect to anything other than a mating
Type I (Q.C.C.1) cylinder valve.
IMPORTANT:
When installing the Crown Verity built-in cabinet with propane storage,
the bottom of the cabinet there must be a minimum clearance of 2 in (50.8 mm)
between the floor of the LP gas cylinder enclosure and the ground.
FIGURE 7. VENTILATION REQUIREMENTS FOR BUILT-IN CABINETS
WITH PROPANE CYLINDER STORAGE.