9
www.napoleonreplaces.com
OPERATION
WARNING!
If you do not follow these instrucons exactly a re or explosion may result causing prop
erty
damage, personal injury or loss of life.
Upon compleng the gas line connecon, a small amount of air will be in the lines. When rst lighng the
burner, it will take a few seconds for the lines to purge themselves of this air.
Once the purging is complete, the burner will light and operate as indicated in the instrucon manual. Subse
quent
lighng of the appliance will not require such pruging unless the gas supply has been disconnected.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. This appliance must be lit by hand while following these instrucons exactly.
B. Before operang smell all around the appliance area for gas and next to the oor because some gas is
heavier than air and will sele on the oor.
C. Use only your hand to turn the manual gas control valve. Never use tools. If the valve will not turn by hand,
do not try to repair it. Call a qualied service technician. Force or aempted repair may result in a re or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualied service technician to
inspect the appliance and replace any part of the control system and any gas control which has been underwater.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; Do not use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instrucons.
• If you cannot reach your gas supplier, call the re department.
LIGHTING INSTRUCTIONS:
1. Locate the manual gas control valve.
2. Place the restarter near the burner ports on top of the burner. Light the restarter. For a Natural Gas unit,
turn on the ON/OFF valve slowly at the unit. For a LP unit, turn the valve in the LP tank counter clockwise all
the way and then turn on the ON/OFF valve slowly at the unit.
3. If the burner does not light before the re starter goes out, immediately turn the gas o.
4. Wait at least ve (5) minutes to clear out any gas. Then smell for gas including near the base of the unit. If you
smell gas, STOP! Refer to the safety informaon in the owner’s manual. If you don’t smell gas, repeat step 2.
TO TURN OFF GAS:
Turn the ON/OFF valve to the o posion at the unit for Natural Gas unit.
For LP unit, turn the ON/O valve to the o poson at the unit and then turn the valve on the LP tank to the
OFF posion clockwise.
Note: The propane regulator in this appliance is equipped with a low ow protecon device. Unless the
propane cylinder valve is opened before the appliance valve, the gas ow will be reduced resulng in a very
small ame. To reset this device, shut o the appliance valve, then the propane cylinder valve. Next, diconnect
the regulator adaptor from the tank and then reconnect. Follow the lighng procedure ensuring the propane
cylinder valve is opened before the unit is.