NXR AK3605LP 36 Inch Professional Gas Range with 6 German To

User Manual - Page 16

For AK3605LP.

PDF File Manual, 30 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Grounding
The power cord is equipped with a three-prong (grounding) plug which mates
with a standard three-prong grounding wall receptacle to minimize the
possibility of electrical shock hazard from the range.
All cord connected appliance shall include instructions relative to location of
the wall receptacle and a warning to the user to disconnect the electrical supply
before serving the appliance.
Where a standard two-prong wall receptacle is encountered,it is the
responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle. Do not cut or remove the
grounding prong from the power cord.
Connect Range to Gas Supply
Install a manual gas line shut-off valve in the gas line in an easily accessed
location outside the range in the gas piping external to the appliance for the
purpose of turning on or shutting off gas to the appliance.
Install male ½” flare union adapter to ½” NPT internal thread elbow at inlet of
regulator. On models equipped with standard twin burners, install the male
pipe thread end of the ½” flare union adapter to the ½” NPT internal thread at
inlet of pressure regulator.Use a wrench on the regulator fitting to avoid
damage.
Install male ½” or ¾” flare union adapter to the NPT internal thread of the
manual shut-off valve,taking care to secure the shut-off valve to keep it from
turning.
The gas supply pressure for checking the regulator setting is 6in (Natural Gas)
and 11inchLP gasconnect flexible gas line connector to the regulator on
the range.Position range to permit connection at the shut-off valve.
When all connections have been made,check that all range controls are in the
“off” position and turn on the main gas supply valve.
Leak testing of the appliance shall be conducted according to the
manufacture‟s instructions.Use some soap water (50% water and 50% soap) or
a leak detector at all joints and connections to check for leaks in the system.
Do not use a flame to check for gas leaks.
The appliance must be isolated from the building‟s gas supply piping system
by closing its individual manual shut-off valve during any pressure testing of
the gas supply piping system at test pressure equal to or less than ½ psig
(3.5kPa).
INSTALLATION INSTRUCTIONS
16
Loading ...
Loading ...
Loading ...