WARNI NG
A strong gas smell, or the hissing sound of
gas indicates a serious problem with your
gas grill or the LP gas tank. Failure to
immediately follow the steps listed below
could result in a fire or explosion that could
cause serious bodily injury, death, or prop-
erty damage.
Shut off gas supply to the gas grill.
Turn the Control Knobs to OFF position.
Put out any flame with a fire extinguisher.
Open Grill Lid.
Get away from the LP gas tank.
Do not try to fix the problem yourself.
If odor continues or you have a fire you
cannot extinguish, call your fire
department. Do not call near the LP gas
tank because
your telephone is an electrical device and
could create a spark resulting in fire
and/or explosion.
NOTE: The normal flow of gas through the
regulator and hose assembly can create a
humming noise. A low volume of noise is
perfectly normal and will not interfere with
operation of the grill. If humming noise is
loud and excessive you may need to purge
air from the gas line or reset the regulator
excess gas flow device. This purging proce-
dure should be done every time a new LP
gas tank is connected to your grill. For help
with this procedure refer to page 15, step 4,
or call the Customer Service Helptine for
assistance.
Basic Lighting Procedures
1. Familiarize yourself with the safety guidelines at
the front of this manual. Do not smoke while
lighting grill or checking gas supply connections.
2. Be sure the LP gas tank is filled.
3. Check that the end of each Burner Tube is properly
located over each Valve Orifice.
4. Make sure all gas connections are securely
tightened.
5. Open the Grill Lid or Side Burner Lid, depending on
the burner you are lighting.
/!X,WARNING
Failure to open Grill Lid during the
lighting procedures could result in a fire
or explosion that could cause serious
bodily injury, death, or property damage.
6. Set Control Knobs to OFF and open the LP gas
tank valve slowly until 1/4 to 1/2 open.
Open LP
gas tank
OFF
7. Push and turn the LEFT Control Knob to HIGH.
Checking For LP Gas Leaks
Never test for leaks with a flame. Prior to first
use, at the beginning of each season, or every
time your LP gas tank is changed, you must
check for gas leaks. Follow these four steps:
1. Make a soap solution by mixing one part
liquid detergent and one part water.
2. Turn the grill Control Knobs to the full OFF
position, then turn the gas ON at source.
3. Apply the soap solution to all gas
connections. If bubbles appear in the soap
solution the connections are not properly
sealed. Check each fitting and tighten or
repair as necessary.
4. If you have a gas leak that you cannot
repair, turn off the gas at the source, discon-
nect fuel line from your grill and call
1-800-4-MY-HOME ®or your gas supplier for
repair assistance.
14
OFF
HIGH Q
8. Immediately press the Electric Ignitor for 3-4
seconds to light the Burner.
PRESS
©
9. If the burner does not light, turn the Control Knob
to OFF, wait 5 minutes for gas to clear, then retry.
10. Once the left grill burner is ignited, the adjacent
burner can be lit by simply turning its Control Knob
to HIGH.
11. Adjust Control Knobs to your desired cooking
temperature.