Your Aspire grill for use with Natural Gas is supplied with its own regulator which MUST be installed. If
this regulator needs to be replaced, use only the type specified by Hestan for this appliance.
To connect the regulator / hose assembly follow the next steps:
1. Locate the regulator and gas connection point in the rear right side of your grill (in cart-mounted models,
remove the rear panel to gain access).
2. Install the natural gas regulator as shown. Connect gas supply using a minimum 1/2” diameter
flexible (semi–rigid) stainless steel gas hose, no more than 48” (1.22m) in length. The hose as well
as the connectors must comply with the
Standard for Connectors for Outdoor Gas Appliances
and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation. Use the
appropriate thread sealant on all connections.
3. Proceed to LEAK TESTING section.
GAS CONNECTIONS
(continued)
GAS CONNECTION - LIQUID PROPANE (LP) CYLINDER
Your Aspire grill for use with
LP gas is supplied with a two-
stage regulator/hose assembly for
connection to a standard 20 lb. LP
gas cylinder. This assembly must
be used WITHOUT alteration. If
this assembly needs to be replaced,
contact your Hestan dealer for
genuine replacement P/N 014309.
NOTE: To ensure proper heating
performance of this appliance,
verify that the supply pressure
is adequate. Use only the gas
pressure regulator supplied with
this appliance. This regulator is set
to maintain 10 inch WC (2.49 kPa)
oulet (manifold) pressure.
2-STG. LP
REGULATOR / HOSE
ASSEMBLY
ADAPTER, 3/8 FLARE
X 1/2 NPT FEMALE
(SHIPPED LOOSE)
20lb LP T
(SUPPLIED BY
CUSTOMER)
TYPICAL ASPIRE GRILL
(36” MODEL SHOWN)
To connect the regulator / hose assembly follow these steps:
1. Locate the regulator and gas connection point in the rear right side of your grill (in cart-mounted models,
remove the rear panel to gain access).
2. Connect the 3/8” Flare (compression flare fitting) X 1/2” NPT female adapter to the grill manifold pipe as
shown. Connect the regulator/hose assembly to the adapter.
3. Connect the regulator/hose assembly to a standard 20 lb. LP cylinder. The hose as well as the connectors
must comply with the
Standard for Connectors for Outdoor Gas Appliances and Manufactured Homes,
ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation. Use the appropriate thread sealant on all
thread connections.
4. Proceed to LEAK TESTING section.