Problem Possible cause Remedy
Drying cycle too
long
5)
The filter is clogged. Clean the filter.
The load is too large. Do not exceed the maximum load
size.
The laundry was not spun suffi‐
ciently.
Spin the laundry well in the wash‐
ing machine.
Too low or too high room tempera‐
ture - this is not the appliance mal‐
function.
Ensure a room temperature higher
than +5°C and lower than +35°C.
Optimal room temperature to ach‐
ieve best drying results is between
18°-25°C.
1)
Follow the programme description — see the PROGRAMMES chapter .
2)
See the
CARE AND CLEANING
chapter.
3)
Only dryers with the Dryness Level option.
4)
See the HINTS AND TIPS chapter .
5)
Note: After a maximum of 6 hours the drying cycle ends automatically.
11.3 Possible causes of
unsatisfactory drying results:
The filter is clogged. Clogged filter
makes drying inefficient.
The airflow slots are clogged.
The humidity sensor is dirty.
The drum is dirty.
Inadequate default dryness level
settings. See chapter
Adjustment of
default dryness level
Room temperature is too low or too
high. Optimal room temperature is
between 18°-25°C.
12. TECHNICAL DATA
Height x Width x Depth 850 x 596 x 638 mm (maximal 663 mm)
Max. depth with the appliance door open 1108 mm
Max. width with the appliance door open 958 mm
Adjustable height 850 mm (+ 15 mm - feet regulation)
Drum volume 118 l
Maximum load volume 8,0 kg
Voltage 230-240 V
Frequency 50 Hz
Sound power level 66 dB
Necessary fuse 13 A
Total power 900 W