Loading ...
Loading ...
Loading ...
Performance Data Sheet
SmartWaterFiltration System
MWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
'100%safety factors built in for unmetered usage)
Stmldard No. 42: Aesthetic Effects
Parmneter USEPA hlfluent
MCL CJlalle_e ConcenWafion
Chlorine -- 2.0 mg/L + 11)%
T&O -- --
Pmliculate** -- _>10,000 parddes/mI,
Influent
Average
1.96 mg/I,
I
6,400,01_)#/mL
Effluent
Average Maxhnmn
0.06 rag/I, 1).11 rag/I,
I I
58,833#/mI, 150,(_)0#/mI,
% Reduction
Average Minimmn
96.77% 94.74%
I I
9{).14% 97.{)7%
Mill. Required
Reduction
> 50%
_>85(/(,
Standard No. 53: Health Effects
Pariuneter
"litrbkiity
(iysl+
Asbestv)s
Lead at pit 6.5
Lead at pit 8.5
Metvtt U at Ill { 6.5
Met*:ttU at Ill t 8.5
,\ladfior
[ hi(lane
2,4-1)
"Ibxat)hene
Bel/zel/e
Carbofimm
1,4 di&lorobenzene
Mrazine
USEPA
MCL
0.5 NTL
_>9{).{!5%Reduction
_>99% Re(ht(tion
t).t)15 mg/L
t).t)15 mg/L
0.002 mg/L
0.002 mg/L
0.002 rag/I,
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
t).t)75 mg/L
0.003 rag/I,
hffluent
Challe_ ,_ge Concentration
11 k I NqT ***
Mflfimum 50,(X)0 I,
1(F to 1(Js fib( e_!I,; > 10[lm
0.15 rag/I,_+ 1()f_
0.15 rag/I,_+ 1()f_
0.006 mg/L + 10!¢
0.006 mg/L + 10!¢
0.04 rag/I,_+ 10!¢
0.002 rag/I, ± l()f_
0.210 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.080 mg/I, + 10%
t).225 rag/I, + 10%
0.1)(_}rag/I, + 10%
hlfluent
Average
10.5 NTU
118,750 #/I,
57 MF/I,
0.1567 rag/I,
0.1433 mg/I,
0.(X)59 ra!!I,
0.(X)57 ra!!I,
0.0367 rag/I,
0.(X)20 ra!!I,
0.2033 rag/I,
0.0160 rag/I,
0.0145 rag/I,
0.0830 rag/I,
02283 rag/I,
0.0087 rag/I,
Effluent
Average Maxhnmn
0.14 NTU 0.28 N'IT
< 1 #/I, 4#/I,
t).9!)6 MF/I, < 1 MF/I,
<0.001 rag/I, <0.001 rag/I,
< 0.001 mg/L < 0.001 rag/I,
0.000350 mg/L 0.0007 mg/L
0.000325 mg/L 0.0006 mg/L
0.00023 rag/I, 0.0004 mg/L
< 0.00002 rag/I, < 0.(X)002 rag/I,
0.00337 rag/I, 0.011000 rag/I,
0.001(X) rag/I, 0.(X)I(X)0 rag/I,
0.0(X)5(X)rag/I, 0.(X)0500 rag/I,
0.001000 mg/L 0.001000 rag/I,
0.0(X)5(X)rag/I, 0.(X)0500 rag/I,
< 0.0005 rag/I, < 0.0005 mg/I
% Reduction
Average Minimmn
98.54% 97.20%
> 9!).!)9% > 9!).!)9%
99.(_0% 99.39%
99.36% !)9.2!)%
99.30% 99.29%
94.70% 87.50%
93.2t)% 8{).2!)%
9!).?.{% {)8.67%
99.(_)% 98.95%
98.32% 94.50%
93.44% 91.67%
96.51% !)5.83%
98.78% !)8.65%
9{).78% 99.77%
94.22% 93.33%
Tested using a flow rare of O.50 gpm; pressure of 60 psig; pH of Z 5 _+O.5; temp. of 68 ° _+5°F (20 ° _+3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU:Nephelometric Turbidity units
gperafing ,
Specifications
Ca I_a(itv" certified h)r, iu _ to ,:;00 ,("all°ns_ ( l 1:,:;5 1);, u ), to _,six
months for models without a rel_a(ement filter m_tl(ator hoht;
up to one ",ear for models with a replacement filter indicator hght
. •! , . c , c . '
P_ essm e I equn ement: 41)-120 psi (2.8-8.2 bat ), non-shock
Temperature: 33-1 00°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 lpm)
General Installat!on/Operation/Maintenance Requirements
Flush new cartridge at full fl(/w tilt 3 minutes to purge out
trapped aiI:
Replace cartridge when the indicator light flashes (/i" water
fl(/{v rate is i'e(hlced on heir-tied|cater tfifits.
Special Notices
Installation instructi(ms, parts and service axailabilitx; and standard
wail'ants' are iI_cluded with file product when shipped.
This di_nking water svsteln must be nlaintained according to
illantt[acttlr(_ias ii_strtlcOons, iI_duding replacen_ent of filter cartridges.
Do not ttse ;_Jfl/water filet is nficrobiol0gi(Sally unsafe or of unknown'
qualiPv without adequate cfisinfecfi(nl before or after file svstenl.
SvstelllS certified fi)i: cyst reduction inav be used (Ill disinfected water T0_VI_
tliat may contain filtelable cysts.
The contaminants or othei" substances removed or reduced by this
water treatinent svstein are not necessarily in your watei:
Check tot compliance with the state and local laws and regulations.
Note that while the testing was perIimned under standard lal)omtor_
conditions actual pell'Oii/lance ina _, x_u'v. S_,stelns inust be installed _uld
operated in accordance with inalm_actt/rei:'s recolmnei_ded procedures
and gtudehnes.
Standard No. 42: Aesthetic Effecis
Chemical [7nit
Chlorine 'Ihste and Odor
Mechanical Filtralion Unit
Parti(ulate Reduction, Class I
System "[-csted and Certified by NSF lnt( rnational against
ANSIiNSF StandaM 42 & 53 for the reduction of
Standard No. 53: Health Effecis
Chemical Reduction Unit
Alachh)r and Atrazine Reduction
Benzene and Carbofiwan Reduction
1,4 dichlorobenzene and 2,41) Reduction
Lead and Lindane Reduction
Mercm T and Toxaphene Reduction
Mechmfical Filtration [ nit
Tu rbidilv Rcdtlction
(:)st and ,\_,bestos Reduction
Mhl. Required
Redue6on
0.5 NTU
_>9{).{}5%
_>9!)%
0.010 rag/I,
0.010 rag/I,
0.002 rag/I,
0.002 rag/I,
0.002 rag/I,
0.0002 mg/I,
0.070 rag/I,
0.003 rag/I,
0.005 rag/I,
t).t)4mg/I
t).t)75rag/I,
0.003 rag/I,
Ratc, d Service ('apaciD: 300 gaI
Conditions of ( err|flea ti0n:
DO not use whele _,_atet 15 nlicl obiologically mtsafe ol vdfh'_ at_i of lulkllovcn qttallty, except that systems cedlfied fol
cy_l I edtlchon Inay h_ tlsed oi1 distil fected _Aatels ttla_ lllay colltaii1 fii_el at de cy_ls
Manufactured tk)r: (;en( ml El(cn-ic Company, Louisville, txN 40225
EPA EST. No. 070595-MN4101
/9
StaTe of Caliibmia
Dcpai_nlellt of Hcatth Selvlces
Water Treatment Device
Certificate Number
05- 1698
Da_cIssued: Febmal_ 2.2OO_
l'l'at[¢qnark/Mot[_,[ I)¢,si_nati0n lloplac_,rtlenl Element',
MWF MWF
Ma nufllct in'f,r: GeneraI Eiech'ic C01npa:ay
Loading ...
Loading ...
Loading ...