13
INSTALLATION
12
INSTALLATION
Adapting the cooker
another type of gas
This operation may only be carried out by
.nosrep desirohtua yletairporppa na
To adapt the cooker to be
selzzon renrub eht ,sag fo epyt rehtona
must be exchanged and the flame adjusted.
Caution!
When leaving the factory, burners are
adapted to use the gas specified on their
data plates and guarantee cards.
In order to adapt the cooker to burn a
different type of gas, you should:
Exchange nozzles (see tables below),
Adjust the flame intensity.
Burner turndown flame must also be adjusted to 25% of the
A correct flame has distinct internal cones of blue colour. A short, humming
flame or long, yellow and smoking one, without clearly outlined cones, shows improper
quality of gas in the household piping or a damaged or soiled burner. In order to cheak a
flame, heat a burner for around 10 minutes with a full flame, and next turn the valve knob
to the turndown flame position. The flame should not go out or jump onto the nozzles.
Hotplate burners do not require adjustment of primary air.
high flame, refer to page 13 for adjustment screw location.
In order to perform the turndown adjustment, remove the gas burner control knobs.
When converting to a different gas type refer to page 10; gas connection.
Injector Table
Upright
Burner
Gas type
Injector
Size(mm)
TPP
(kPa)
NGC
(MJ/h)
Auxiliary
Semi-rapid
Rapid
Wok
Auxiliary
Semi-rapid
Rapid
Wok
Natural gas
Universal
LPG
0.88
1.17
1.57
1.30
0.52
0.68
0.88
0.73
1.0
2.75
3.6
6.3
10.8
14.4
3.6
6.3
10.8
14.4
Total Gas Consumption
900mm
Natural gas 41.4MJ/h - Universal LPG 41.4MJ/h
900mm
Electrical connections
Electric connection may be carried
out by qualified service personnel
only!
Wrong connection may permanently
damage parts of the appliance and
render your warranty void!
Mains voltage of the user(240V)must
be verified with the measuring device!
Three separrating switches should be
placed in accordance with the mains
connection.
Mains lead behind the cooker must be
placed in such manner to avoid
touching the back panel of the cooker
because of the heat it develops during
operation.
The mains lead extension may be
made by qualified personnel only.
Repairs of electrical parts may be
carried out only by qualified
electrician.In case of malfunction call
the service center.
Caution!
Fig. B
A knob with a
surface burner
safety valve
Replacement of a burner
nozzle: Unscrew the
nozzle with special socket
spanner No 7 and replace
with a new one according
to the type of gas
(see tables)
In cookers with a safety device, a knob with
a surface burner safety valve is used, (Fig. B).
Knobs should be adjusted with the burner
switched on and set to the economical
flame position, using an adjustment
screwdriver of the 2.5mm size.
Adapting the appliance to a different
type of gas than that indicated by the
manufacturer of the cooker on the data
plate, or purchasing a cooker for a different
type of gas than supplied to thehouse, is
exclusively the responsibility of the user
and the fitter.
After adjustment is completed, affix a
label to the cooker indicating the type
of gas to which the cooker is now adapted.