4. Touch the relevant SELECTION OF COOKING ZONE-sensor to cancel the boost-
mode. The indicator beneath the sensor flashes. Then touch the BOOSTER sensor
and the relevant cooking zone will operate in the previous setting.
5. All cooking zones can be operated with the booster-function separately. When
using the booster- function, please deactivate a running booster-function of the
same group (look at chapter 3.8); otherwise p and 9 will alternately flash on the
display of the selected cooking zone and power level 9 is set automatically.
3.8 Energy management
The cooking zones are divided relevant to their location and number of phases.
Each group has a maximum electric load of 3680 W.
The energy management divides the power between the groups, which are
connected with the same phase.
The energy management is activated when the maximum load of the cooking
zones which are connected to a single phase exceeds 3680 W.
The energy management reduces the energy supply of the cooking zones which
are connected to the same phase.
The indicators of the reduced cooking zones display two power levels.
Group A:
Both zones can be operated with full power as their total power is
3500 W.
Group A Group B
Loading ...
Loading ...
Loading ...