Loading ...
Loading ...
Loading ...
every repaired unit. Also, tubing and ducts should be routed per Photograph
#1, section 17)
14. Wheels
Remove six screws from the main housing
Remove window, flow indicator cap and belt access door
Unsnap main housing from front of base
Remove main housing assembly
Remove clip ring on wheel axle
Remove wheel and axle assembly
Replace and reassemble
(Note: When reattaching the main housing, it is critical that the upholstery
duct tab be properly located into the slot on top of the motor cover to insure
proper alignment of main housing over duct. This tab may pop out of the slot
each time the housing is removed, so check for this condition on every
repaired unit. Also, tubing and duets should be routed per Photograph #1,
section 17).
15. Hose
Remove six screws from the main housing
Remove window, flow indicator cap and belt access door
Unsnap main housing from front of base
Remove main housing assembly
Disconnect hose from air duct
Diseormect hose solution tube
Replace and reassemble
Reattach top cover and secure with six screws (Note: It is eritieai that the
upholstery duct tab be properly located into the slot on top of the motor cover
to insure proper alignment of main housing over duct. This tab may pop out
of the slot each time the housing is removed, so check for this condition on
every repaired unit. Also, tubing and ducts should be routed per Photograph
#1, section 17)
16. Brush Roll
Recline handle and place base assembly upside down on a flat surface
Remove two red pivot arm retainers
Remove pivot arms and belt
Remove old brush roll
Insert new brush roll into cogged belt
Reattach pivot arms and seat brush roll
Reattach red pivot arm retainers (Note: The guard on the pivot arm must face
down towards the floor)
03/03/99 Rev C