Loading ...
Loading ...
Loading ...
9
Majestic • Owner’s Manual MARQ36IN, MARQ42IN • 2270-981 Rev. i • 8/17
E. Before Lighting Appliance
Before operating this replace for the rst time, have a
qualied service technician:
Verify all shipping materials have been removed from
inside and/or underneath the rebox.
Review proper placement of logs, ember material and/or
other decorative materials.
Check the wiring.
Check the air shutter adjustment.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate replace with xed glass assembly removed.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
22 IN.
34 IN.
40 IN.
46 IN.
52 IN. MIN.
CEILING
28 IN.
APPLIANCE FRONT
FIREPLACE OPENING
165°F+
150°F
160°F
155°F
160°F
16 IN.
180°F+
10 IN.
230°F+
Figure 3.4. Good Faith Wall Surface Temperatures Above Appliance
D. Good Faith Wall Surface/TV Guidelines
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certication. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.