Craftsman CMMT17735V V-Series 3/8 in Drive X-Tract Technology Hex Bit Socket Set 12 pc

User Manual - Page 9

For CMMT17735V.

PDF File Manual, 35 pages, Read Online | Download pdf file

CMMT17735V photo
Loading ...
Loading ...
Loading ...
7
ENGLISH
ENGLISH
6
On(I)/Off(O) Switch:
4
in the On(I)
position to provide automatic power to the pressure switch
Pressure Switch (not shown): The pressure switch
automatically starts the motor when the air tank pressure
drops below the factory set “cut-in” pressure. It stops the
motor when the air tank pressure reaches the factory set
Safety Valve: If the pressure switch does not shut off the
air compressor at its “cut-out” pressure setting, the safety
will protect against high pressure by “popping out”
at its factory set pressure (slightly higher than the pressure
Tank Pressure Gauge:
5
Outlet Pressure Gauge:
9
indicates the air pressure available at the outlet side of the
regulator. This pressure is controlled by the regulator and is
always less than or equal to the tank pressure.
Regulator: Controls the air pressure shown on
7
clockwise to increase pressure and counterclockwise to
Cooling System (not shown): This compressor contains
an advanced design cooling system. At the heart of this
cooling system is an engineered fan. It is perfectly normal
for this fan to blow air through the vent holes in large
amounts. You know that the cooling system is working
Air Compressor Pump (not shown): Compresses air into
the air tank. Working air is not available until the compressor
has raised the air tank pressure above that required at the
Drain Valve:
10
is located at the base of
the air tank and is used to drain condensation at the end of
Check Valve (not shown): When the air compressor is
operating, the check valve is “open”, allowing compressed
air to enter the air tank. When the air compressor reaches
“cut-out” pressure, the check valve “closes”, allowing air
Motor Overload Protector (not shown): The motor has
a thermal overload protector. If the motor overheats for
any reason, the overload protector will shut off the motor.
The motor must be allowed to cool down before restarting.
1.
2.
3. Plug the power cord into the correct branch
4. Set the On/Off switch to “On” position.
Quick Connects :
6
accepts industrial and automotive quick connect plugs.
The two quick connect bodies allow the use of two
tools at the same time.
How to Use Your Unit (Fig. A, B)
How to Stop
1. to “Off”.
2.
Before Starting
WARNING: Do not operate this unit until
you read this instruction manual for safety,
Before Each Start-Up
1. to “Off”.
2. Plug the power cord into the correct branch circuit
receptacle.
(Refer to Voltage and Circuit Protection
paragraph in the Installation section of this manual.)
3.
counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 PSI
Fig. B
4.
5. Ensure all covers and labels are in place, legible (for
labels) and securely mounted. Do not use compressor
WARNING: Risk of unsafe operation. Firmly grasp
air hose in hand when installing or disconnecting
WARNING: Risk of unsafe operation. Do not use
.
NOTE: This unit is equipped with quick connects
6
. The
hose or accessory being connected will require a quick
WARNING: Risk of Bursting. Too much air pressure
causes a hazardous risk of bursting. Check the
manufacturers maximum pressure rating for air
tools and accessories. The regulator outlet pressure
NOTICE: Risk of property damage. Compressed air
from the unit may contain wa ter condensation and
oil mist. Do not spray un l tered air at an item that
could be damaged by moisture. Some air tools and
accessories may require ltered air. Read the
in struc
7
6
7
ENGLISH
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and disconnect it from
power source before making any adjustments or
removing/installing attachments or accessories.
An accidental start-up
WARNING: Risk of unsafe operation. Unit
cycles automatically when power is on.
When performing maintenance, you may be
exposed to voltage sources, compressed air,
or moving parts. Personal injuries can occur.
Before performing any maintenance or repair,
disconnect power source from the compressor
Customer Responsibilities
Before each
use
Daily or after
each use
See tank
warning
label
Check Safety Valve
X
Drain Tank X
Remove tank from
service
X
1
1- For more information,
call our Customer Care Center at 1-888-895-4549.
NOTE: See Operation
To Check Safety Valve (Fig. C)
WARNING: Risk of Bursting. If the safety valve
does not work properly, over-pressurization may
occur, causing air tank rupture or an explosion.
WARNING: Risk from Flying Objects. Always
wear certified safety equipment: ANSI Z87.1 eye
Before starting compressor, pull the ring on the safety
to make sure that the safety valve operates freely. If
the valve is stuck or does not operate smoothly, it must be
How to Start
1. to “On” and allow tank pressure
to build. Motor will stop when tank pressure reaches
2.
clockwise to increase pressure
WARNING: Risk of unsafe operation. If any
unusual noise or vibration is noticed, stop the
compressor immediately and have it checked by
Fig. C
To Drain Tank (Fig. A, D)
WARNING: Risk of Unsafe Operation. Air tanks
contain high pressure air. Keep face and other
body parts away from outlet of drain. Use
draining as debris can be kicked up into face.
WARNING: Risk from noise. Always wear proper
hearing protection during use. Under some
conditions and duration of use, noise from this
NOTE: All compressed air systems generate condensate
that accumulates in any drain point (e.g., tanks, filter,
aftercoolers, dryers). This condensate contains lubricating
oil and/or substances which may be regulated and must be
disposed of in accordance with local, state, and federal laws
WARNING: Risk of Bursting. Water will condense
in the air tank. If not drained, water will corrode
and weaken the air tank causing a risk of air
NOTICE: Risk of Property Damage. Drain water
from air tank may contain oil and rust which can
1.
to “Off”.
2.
counterclockwise to set the
3.
4. Place a suitable container under the drain valve to
5.
allowing air to bleed from
6.
on
8
Loading ...
Loading ...
Loading ...