5. Fasten the plastic water line to the refrigerator with a “P”
clamp. Slide the plastic water line into the retainer.
6. Turn on water supply to refrigerator and check for leaks.
Correct any leaks.
Style 2
1. Remove plastic cap from water valve inlet port. Attach the
copper tube to the valve inlet using a compression nut
and sleeve as shown. Tighten the compression nut. Do not
overtighten. Conrm copper tubing is secure by pulling on the
tubing.
2. Create a service loop with the copper tubing. Avoid kinks
when coiling the tubing. Fasten the copper tubing to the
refrigerator cabinet with a “P” clamp.
3. Turn on water supply to refrigerator and check for leaks.
Correct any leaks.
Complete the Installation
1. Plug into a grounded 3 prong outlet.
2. Flush the water system. See “Water and Ice Dispensers.”
Refrigerator Doors and Drawer
All graphics referenced in the following instructions are included
later in this section after “Final Steps.”
Remove and Replace Handles
To Remove Handles:
1. Grasp the lower part of the handle rmly, slide the handle up
and pull the handle straight out from the door. See Handle
graphic.
To Replace Handles:
1. Position the handle so that the large holes in the mounting
clips are down and align the holes with the door studs.
2. Rotate the handle so that the mounting clips are at against
the door and slide the handle down to engage. See Handle
graphic.
Remove Doors and Hinges
IMPORTANT:
Remove food and any adjustable door or utility bins from
doors.
Keep the refrigerator doors closed until you are ready to lift
them free from the cabinet.
A
B
C
A. Brass nut
B. Compression sleeve
C. “P” clamp
B
A
C
D
A. Copper tubing
B. “P” clamp
C. Compression nut
D. Compression sleeve
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Electrical Shock Hazard
Disconnect power before removing doors.