Page 10
Operating
Instructions
COOL operation
Press the “MODE” button until the “COOL
indicator light comes on.
Press the ADJUST buttons Up (
) or Down ( )
to select your desired room temperature.
The temperature can be set within a range of
60°F~86°F/16°C~30°C.
Press theFAN SPEED” button to choose the fan
speed.
HEAT operation (for heat model)
Press the “MODE” button until the “HEAT”
indicator light comes on.
Press the ADJUST buttons Up (
) or Down ( )
to select your desired room temperature.
The temperature can be set within a range of
60°F~86°F/16°C~30°C.
Press the “FAN SPEED” button to choose the fan
speed.
When entering heat mode, the fan may start
slower than expected. For some models, the fan
speed cannot be adjusted while in HEAT mode.
DRY operation
Press the “MODE” button until the “DRY”
indicator light comes on.
While in this mode, you cannot select a fan
speed. The fan motor operates at AUTO speed.
Keep windows and doors closed for the best
dehumidifying effect.
AUTO operation
When you set the air conditioner to AUTO mode,
it will automatically select cooling, heating (Heat
models only) or fan only operation depending
on what temperature you have selected and the
current room temperature.
The air
conditioner will control room temperature
automatically according to the temperature point
set by you.
Under AUTO mode, you cannot select the fan
speed.
FAN operation
Press theMODE” button until the
”FANindicator light comes on.
Press the “FAN SPEED” button to
choose the fan speed. The temperature
cannot be adjusted.
Do not connect the duct to a window.
TIMER: Auto Start/Stop Operation
When the unit is on, pressing the
Timer button will initiate the Auto stop
program. The TIMER OFF indicator light
illuminates. Press the Up (
) or Down
(
) button to select the desired time.
Press the TIMER button again within
5 seconds. The Auto start program is
initiated and the TIMER ON indicator
light illuminates. Press the Up (
) or
Down (
) button to select the desired
Auto start time.
When the unit is off, press the Timer
button to initiate the Auto start program.
Pressing it again within five seconds will
initiate the Auto stop program.
Press or hold the Up (
) or Down ( )
button to change the Auto time by 0.5
hour increments, up to 10 hours, then
at 1 hour increments up to 24 hours.
The control will count down the time
remaining until start.
The system will automatically
revert back to display the previous
temperature setting if there is no
operation within 5 seconds.
Turning the unit ON or OFF at any time
or adjusting the timer setting to 0.0
will cancel the Auto Start/Stop timer
program.
Should a malfunction occur, the Auto
Start/Stop timed program will also be
cancelled.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error (select
models).
E4 - Display panel communication error.
P1 - Bottom tray is full - Connect the drain hose and
drain the collected water away. If protection
code repeats, call for service.
NOTICE
When one of these error codes occurs,
turn off the unit and check for any
obstructions. Restart the Unit. If the
malfunction persists, turn off the unit
and unplug the power cord and contact
customer service at 1-866-646-4332.