Loading ...
Loading ...
Loading ...
4
GAS REGULATOR CHECK / CONVERSION
If the Teppanyaki Griddle is factory built for natural gas, the regulator supplied is set for 4” water
column. The regulator is convertible to 10 in wc (2.49 kPa) for system LP application. Do not use with a 20-lb
LP cylinder. Make sure that the regulator is set for the correct gas type. To check, remove the brass hex cap.
You will find the conversion plastic pin attached to the cap to the underside of the cap. If the disc (1/2 in.
diameter) of the pin is close to the cap, then the regulator is set for natural gas. If the disc is at the tip of the pin,
away from the brass cap, the regulator is set for system LP application. To convert to natural gas, remove the
plastic conversion pin and invert and replace it back in a manner such that the disc is close to the brass cap. For
both natural and LP, the maximum inlet pressure is 14 in wc (3.5 kPa).
WARNING:
DO NOT STORE SPARE LP-GAS CYLINDER UNDER OR NEAR THIS
APPLIANCE.
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
FAILURE TO DO SO MAY CAUSE FIRE, DEATH, OR SERIOUS INJURY
MAY OCCUR.
USE ONLY A 20-LBS (5 GALLON CAPACITY) GAS CYLINDER.
DO NOT USE A DENTED OR RUSTED LP CYLINDER.
NEVER USE A CYLINDER WITH A DAMAGED VALVE.
ALWAYS CHECK FOR LEAKS AFTER CHANGING THE LP CYLINDER.
THE LP PRESSURE REGULATOR AND HOSE SUPPLIED WITH THIS UNIT
MUST BE USED WITHOUT ALTERATION.
Set to NG
Set to LP
Loading ...
Loading ...
Loading ...