NATURAL GAS INSTALLATION
A typical natural gas installation is shown below. Make sure that the factory-supplied regulator is used
and installed with the arrow mark on the regulator pointing towards the Teppanyaki Griddle. Use only pipe
sealants that are approved for use with natural and LP gases. An installer-supplied gas shutoff valve must be
installed in an accessible location.
Please note, when pressure testing, the following statements must be adhered to:
This gas appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at the test pressures in excess of 1/2 psi (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).
CAUTION: Provide adequate ventilation holes in the enclosure for safety purposes in
the event of a gas leak.