Samsung FE-N500WX/XAA-00 electric freestanding range

User Manual - Page 5

For FE-N500WX/XAA-00.

PDF File Manual, 12 pages, Download pdf file

Loading ...
Loading ...
Loading ...
connecting
the
power
STEP
1.
MEETING
ELECTRICAL
CONNECTION
REQUIREMENTS
CAUTION
CAUTION
For
personal
safety,
do
not
use
an
extension
cord
with
this
appliance.
Remove
house
fuse
or
open
circuit
breaker
before
beginning
installation.
This
appliance
must
be
supplied
with
the
proper
voltage
and
frequency,
and
connected
to
an
individual
properly
grounded
branch
circuit,
protected
by
a
circuit
breaker
or
fuse
having
amperage
as
specified
on
the
rating
plate.
The
rating
plate
is
located
above
the
drawer
on
the
oven
frame.
(Fig.
1
or
Fig.
2)
We
recommend
you
have
the
electrical
wiring
and
hookup
of
your
range
connected
by
a
qualified
electrician.
After
installation,
nave
the
electrician
show
you
where
your
main
range
disconnect
is
located.
Check
with
your
local
utilities
for
electrical
codes
which
apply
in
your
area.
Failure
to
wire
your
oven
according
to
governing
codes
could
result
in
a
hazardous
condition.
If
there
are
no
local
codes,
your
range
must
be
wired
and
-
fused
to
meet
the
requirements
of
the
National
Electrical
Code,
ANSI/NFPA
No.
(Fig.
1)
70-Latest
Edition.
You
can
get
a
copy
by
writing:
National
Fire
Protection
Association
Batterymarch
Park
Quincy,
MA
02269
daMOd
SHL
ONILOANNOO
dO
(Fig.
2)
Effective
January
1,
1996,
the
National
Electrical
Code
requires
that
new
construction
(not
existing)
utilize
a
4-conductor
connection
to
an
electric
range.
When
installing
an
electric
range
in
new
construction,
follow
Steps
2
and
3
for
4-wire
connection.
You
must
use
a
3-wire,
single-phase
A.C.
208Y/120
Volt
or
240/120
Volt,
60
hertz
electrical
system.
If
the
electrical
service
provided
does
not
meet
the
above
specifications,
have
a
licensed
electrician
install
an
approved
outlet.
Use
only
a
3-conductor
or
a
4-conductor
UL-listed
range
cord.
These
cords
may
be
provided
with
ring
terminals
on
wire
and
a
strain
relief
device.
Arange
cord
rated
at
40
amps
with
125/250
minimum
volt
range
is
required.
A
50
amp
range
cord
is
not
recommended
but
if
used,
it
should
be
marked
for
use
with
nominal
136”
diameter
connection
openings.
Care should
be
taken
to
center
the
cable
and
strain
relief
within
the
knockout
hole
to
keep
the
edge
from
damaging
the
cable.
®
Because
range
terminals
are
not
accessible
after
range
is
in
position,
flexible
service
conduit
or
cord
must
be
used.
NOTE
If
conduit
is
being
used,
go
to
Step
4
on
page
9.
ALL
NEW
BRANCH-CIRCUIT
CONSTRUCTIONS,
MOBILE
HOMES,
RECREATIONAL
VEHICLES
AND
INSTALLATIONS
WHERE
LOCAL
CODES
DO
NOT
ALLOW
GROUNDING
THROUGH
NEUTRAL,
REQUIRE
A
4-CONDUCTOR
UL-LISTED
RANGE
CORD.
Connecting
the
power
5
Installation-USA
DG68-00108E-01_EN.indd
5
2011-03-18
i
4:06:27
Loading ...
Loading ...