4.1 GENERAL SPECIFICATIONS
Auto ranges and manual range.
Over range protection for all ranges.
Max. Voltage Between Terminals And Earth Ground: 600V DC or AC
Operating Altitude: 2000 meters (7000 ft.)maximum
LCD Display: 19.5mm height character
Max. Show Value: 1999 (3 1/2)
Polarity Indication: ‘-’indicates negative polarity.
Over range Indication: Display 'OL'
Sampling Time: approx. 0.4 second
Unit showing: showing of function and electrical capacity.
Low Battery Indication: “ ” displayed
Auto power off time: 15 min.
Power Supply: 1.5V×2 AAA batteries.
Operating Temperature: 0°C to 40°C (32°F to 104°F)
3.1.15 Storage Temperature: -10°C to 50°C (10°F to 122°F)
3.1.16 Dimension: 150×74×43mm
3.1.17 Weight: approx. 233 g (including battery)
10.1 KEYS EXPLANATIONS
• "FUNC" button:
Measuring the current and voltage, the meter will switch between DC and AC range.
or when measuring the resistance, diode and continuity, the meter will switch to the
correct measurement function.
• "HOLD" button:
Used to hold data on screen.
• "MAX" button:
Used to hold maximum value on screen.
• " " button:
This button is used to the switch on/off back light.
DC Voltage
Range Accuracy Resolution
200mV 0.1mV
2V ± (0.7% of rdg + 3 digits) 0.001V
20V 0.01V
200V 0.1V
600V ± (1.0% of rdg + 3 digits) 1V
Input Impedance: 10M
Overload Protection:
200mV range: 250V DC or AC rms,
2V-600V ranges: 600V DC or AC rms.
Max. Input Voltage: 600V DC
10. EXPLANATION OF SYMBOLS