Installation
45
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 - 30/37 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 4.0
Nozzle diameter (1/100 mm) 50 65 100
Pre-chamber (printed on nozzle) - - -
Reduced flow rate (W) 400 500 1400
Rated flow rate G30 (g/h) 73 131 291
Rated flow rate G31 (g/h) 71 129 286
8 LPG G30/31 - 37 mbar AUX SR UR2
Rated heating capacity (kW) 1.1 1.9 4.1
Nozzle diameter (1/100 mm) 50 65 95
Pre-chamber (printed on nozzle) - - -
Reduced flow rate (W) 450 550 1500
Rated flow rate G30 (g/h) 80 138 298
Rated flow rate G31 (g/h) 79 136 293
9 LPG G30/31 - 50 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 4.1
Nozzle diameter (1/100 mm) 43 58 80
Pre-chamber (printed on nozzle) (H2) (M) (F4)
Reduced flow rate (W) 400 500 1400
Rated flow rate G30 (g/h) 73 131 298
Rated flow rate G31 (g/h) 71 129 293
10 Town gas G110 - 8 mbar AUX SR UR2
Rated heating capacity (kW) 1.0 1.8 3.5
Nozzle diameter (1/100 mm) 145 185 340
Pre-chamber (printed on nozzle) /8 /2 ST8080-02
Reduced flow rate (W) 400 500 1200