DRYER VENTING REQUIREMENTS
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, chimney,
wall, ceiling, attic, crawlspace, or a concealed space of a building.
Only rigid or flexible metal vent shall be used for exhausting.
4" (102 mm) Heavy, metal exhaust vent
Only a 4" (102 mm) heavy, metal exhaust vent and clamps may
be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may result in
reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
The total length should not exceed 7¾ ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire length
of the system and make sure exhaust hood is not plugged with lint.
Replace plastic or metal foil vents with rigid metal or flexible metal
vents. Review “Vent System Chart” and if necessary, modify existing
vent system to achieve best drying performance.
Elbows:
45° elbows provide better airflow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into interior of duct and catch
lint. Do not use duct tape.
4"
(102 mm)
Good
Better