Fulgor Milano F6PIR304S1 30 Inch Freestanding Induction Rang

User Manual - Page 15

For F6PIR304S1.

PDF File Manual, 46 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
ENGLISH
Installation Manual
13
to see the appropriate connection type)
3) Connect line 1 (black) and line 2 (red) wires to the
outer terminal block posts with 10-32 hex nuts.
4) Securely tighten hex nuts.
5) Replace terminal block access cover.
B
A
C
D
E
F
A. Terminal block
B. ground strap
C. L1 Black wire
D. L2 Red wire
E. Neutral White wire
F. Ground Link screw
Direct Electrical Connection to the Circuit

If the appliance is connected directly to the circuit
       
armored or non metallic sheathed copper cable (with
grounding wire).
3-WIRE BRANCH CIRCUIT (for US only)
Refer to Figure A:
where local codes allow the connection of GROUND
wire from the range to the branch circuit NEUTRAL
wire (gray or white colored wire):
- If local codes permit, connect the green GROUND
wire from the range and the white wire from the
oven to the branch circuit NEUTRAL wire (gray or
white colored wire).
- Connect the red and black leads from the range
to the corresponding leads in the junction box.
4-WIRE BRANCH CIRCUIT (for US only)
Refer to Figure B:
- Disconnect ground from neutral at free end of
conduit.
- Connect the green GROUND wire from the range
to the GROUND wire in the junction box (bare or
green colored wire).
- Connect the red and black leads from the range
to the corresponding leads in the junction box.
- Connect the white wire from the range to the
NEUTRAL (gray or white) wire in the junction box.
   DO NOT
connect to electrical power supply until appliance
is permanently grounded. Connect the ground wire
before turning on the power.
Red wires
Junction box
Cable from
power supply
White wires
Black wires
UL listed conduit
connector
Cable
from oven
Bare or
green wire
Ungrounded Neutral
B
Cable from
power supply
Junction box
UL listed conduit
connector
Red wires
White wires
Black wires
Cable
from oven
Bare or
green wire
Grounded Neutral
A