INSTALLATION INSTRUCTIONS
It is recommended that the vent system be installed before
hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height maximum
before you select your hood.
To avoid damage or dirt, place a thick, heavy covering over
countertop, cooktop, or range.
1. Disconnect power.
2. Determine which venting method to use: roof or wall.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4.
5.
Using 2 or more people, lift range hood onto covered surface.
Tip the range hood on its top and remove filters and set
aside. See "Range Hood Care" section.
Slide apart the chimney covers.
NOTE: To avoid damage to the chimney covers, do not
remove the plastic coverings at this time.
The chimney section of the hood is shipped assembled. It
must be disassembled for installation.
6. Remove the lower chimney cover from the chimney support
by removing the two Phillips screws on the outside bottom of
the chimney cover.
7. Remove the upper chimney cover from the chimney support
by removing the two Phillips screws on the outside top of the
chimney cover.
8. Determine and mark the centerline on the ceiling where the
hood will be installed, making sure that the hood is centered
over the cooking surface.
9. Tape the template (supplied in the chimney support carton) to
the ceiling and mark the mounting holes, electrical hole and
vent location on the ceiling.
C
A. Template on ceiling
B. Centerline
C. Cooking surface
10. Drill pilot holes in the chimney support mounting hole
locations for your attachment method.
11. Use a 1V4"or 3.0 cm drill bit to drill the hole for the power
supply cable.
12. Cut the hole for the vent system in the ceiling and install the
vent system. See "Venting Requirements" section.
13. If roof or wall does not have a damper, place the round
damper into the exhaust opening of the vent motor housing.
14. Remove the 4 hex washer head wood bolts from the parts
bag and install in previously drilled pilot holes for attaching
chimney support to ceiling. Leave screw heads about 1¼,,
(6.4 mm) away from the ceiling strips.
\\\\\\\\\\ _{_
A. 1/4"(6.4 mm)
15. Run wire through the 1V4"(3.0 cm) electrical hole in the ceiling
according to the National Electrical Code or CSA Standards
and local codes and ordinances. There must be enough
power supply cable from the fused disconnect (or circuit
breaker) box to make the connection in the hood's electrical
wiring box.
16. Use caulk to seal all openings.
NOTE: Do not reconnect power until installation is complete.
Chimney Extension Kit (optional) Installation
IMPORTANT: For this installation, you will need Chimney
Extension Kit Part Number W10271504 (Stainless Steel).
1. Remove chimney extension cover (if factory assembled).
2. Position the chimney extension over the chimney support so
that the outside edges and the electrical holes line up.
8