Napoleon WHVF24N Plazmafire VF24 Series Vent Free Natural Gas Fireplace

User Manual - Page 19

For WHVF24N.

PDF File Manual, 26 pages, Read Online | Download pdf file

WHVF24N photo
Loading ...
Loading ...
Loading ...
W415-1158 / B / 01.09.17
19
EN
8.0 MAINTENANCE
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing. This appliance and its venting system
should be inspected before use and at least annually by a quali ed service person. The appliance area must
be kept clear and free of combustible materials, gasoline or other ammable vapors and liquids. The ow of
combustion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to
expose both assemblies.
2. Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs
clean by vacuuming or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or
are not burning properly.
4. Check to see that the pilot ame is large enough to engulf the ame sensor and/or thermocouple /
thermopile as well as reaches the burner.
5. Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning
which can be distributed in the surrounding living area.
6. Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10
second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer /
distributor.
40 16A
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
DO NOT PAINT THE PILOT ASSEMBLY.
MAINTENANCE
MAINTENANCE
MAINTENANCE
!
WARNING
7. Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.
8. Blow or vacuum any dust or debris from the catalyst cells, ensuring they are all free from obstruction.
Loading ...
Loading ...
Loading ...