Hotpoint AH11H15D3B PTAC Heat Pump Unit 20 amps, 230/208 Volt

OWNER’S MANUAL AND INSTALLATION INSTRUCTIONS - Page 38

For AH11H15D3B. Also, The document are for others Hotpoint models: AH11E07D*, AH11H07D*, AH11E09D*, AH11H09D/E*, AH11E12D*, AH11H12D/E*, AH11E15D*, AH11H15D*

PDF File Manual, 48 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
6 49-5000041 Rev. 5
USO DEL ACONDICIONADOR DE AIRE
Configuración del Interruptor DIP
RETIRO DEL PANEL FRONTAL
/RVFRQWUROHVGHORVLQWHUUXSWRUHV',3VHHQFXHQWUDQXELFDGRV
GHWUiVGHOSDQHOIURQWDODWUDYpVGHXQDDEHUWXUDGHEDMRGHO
panel de control. Para acceder, retire el panel frontal.
/RVLQWHUUXSWRUHV',3VHHQFXHQWUDQDFFHVLEOHVVLQDEULUODFDMD
de control..
/DXQLGDGGHEHUiVHUDSDJDGDSDUDFDPELDUVXHVWDGRGH
forma efectiva.
(PSXMHGHVGHODSDUWH
trasera para liberarlo de las
lengüetas.
/XHJROHYiQWHOR
UP(ON)
DOWN(OFF)
1 2 3 4 1 2 3 4
S1
S2
S3
S4
S5
S6
S7
S8
Heating type
Temperature display type
Control type
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for cooling
Fan CON/CYC for heating
1 2 1 2 3 4
Low temp. Protection
,QWHUUXSWRUHV',3
CONFIGURACIONES DE LOS
INTERRUPTORES DIP
&RQVXOWHODWDEOD\ODILJXUDPiVDEDMRSDUDFRQRFHUODV
FRQILJXUDFLRQHVGHORV,QWHUUXSWRUHV',3\ODVIXQFLRQHVGH
FDGDSRVLFLyQGHORVLQWHUUXSWRUHV',3
Nº.
ARRIBA (ENCENDIDO) ABAJO (APAGADO) Comentarios
6
&DORU(OpFWULFRÒQLFDPHQWH &DOHIDFFLyQ(OpFWULFD\%RPEDGH&DORU Para la unidad con bomba de calor únicamente.
S2
3DQWDOODGH7HPSHUDWXUDHQ) 3DQWDOODGH7HPSHUDWXUDHQ&
S3
7HUPRVWDWRGH3DUHG$FWLYDGR &LFORGHO9HQWLODGRUSDUD&DOHIDFFLRQDU
66
6Ÿ6Ÿ))
6Ÿ6ź))
6ź6Ÿ))
6ź6ź))
'RVFRQILJXUDFLRQHV66VHFRPELQDQSDUD
seleccionar el punto de configuración.
S6
)XQFLRQDPLHQWR&RQWLQXRGHO
9HQWLODGRUSDUD&DOHIDFFLRQDU
&LFORGHO9HQWLODGRUSDUD&DOHIDFFLRQDU
6
)XQFLRQDPLHQWR&RQWLQXRGHO
9HQWLODGRUSDUD5HIULJHUDU
&LFORGHO9HQWLODGRUSDUD5HIULJHUDU
6
Protección de temperatura baja
activada
Protección de temperatura baja
desactivada
2SFLRQDO
6
8VHDOJXQRVWLSRVGHWHUPRVWDWRV
de pared
8VHRWURWHUPRVWDWRGHSDUHGSDUD
HO37$&$FRQGLFLRQDGRUGH$LUHGH
3DTXHWH7HUPLQDO
2SFLRQDO
TABLA DE CONFIGURACIÓN Y DE LOS INTERRUPTORES DIP
NOTA:(QHOPRGRGHFDOHIDFFLyQODWHPSHUDWXUDFRQILJXUDGD
QRSRGUiVHUVXSHULRUD)&
Termostato de Pared Activado
8QWHUPRVWDWRGHSDUHGFDEOHDGRSRGUiVHUFRQHFWDGRDOD
XQLGDG6LVHFRQHFWDHVWHLQWHUUXSWRU',3GHEHUiVHUPRYLGR
DOD3RVLFLyQGHO7HUPRVWDWRGH3DUHG$FWLYDGR$55,%$
DQWHVGHTXHHOWHUPRVWDWRGHSDUHGFRQWUROHODXQLGDG
Protección por temperatura baja (opcional)
6LODXQLGDGVLHQWHTXHODWHPSHUDWXUDGHODVDODHVLQIHULRUD
)&HOPRWRUGHOYHQWLODGRU\ODFDOHIDFFLyQGHODEDQGD
HOpFWULFDVHDFWLYDUiQ\FDOHQWDUiQODVDODKDVWD)&
(OYHQWLODGRUVHGHWLHQHGXUDQWHXQSHUtRGRFRUWRFXDQGROD
temperatura es satisfactoria.
Calor Eléctrico Únicamente (para la unidad de la bomba de
calor únicamente)
(VWDFRQILJXUDFLyQWtSLFDPHQWHHVXVDGDSDUD&DOHIDFFLRQDUHQ
XQD6LWXDFLyQGH(PHUJHQFLD
Interruptores DIP CON/CYC del Ventilador de Calor y Frío
/HSHUPLWHDOYHQWLODGRUIXQFLRQDUHQPRGRVFRQWLQXRVR
por ciclos, mientras la unidad se encuentra en el modo de
calefacción o refrigeración.
CON (Continuo)
/HSHUPLWHDOYHQWLODGRUIXQFLRQDUGHIRUPDFRQWLQXD
KDFLHQGRFLUFXODUDLUHFXDQGRODFRQILJXUDFLyQGH
WHPSHUDWXUDVHDVDWLVIDFWRULD(VWHLQWHUUXSWRUD\XGDD
PDQWHQHUODWHPSHUDWXUDGHODVDODPiVFHUFDDDTXHOODGH
la configuración del termostato.
CYC (Ciclo)
(VWDFRQILJXUDFLyQOHSHUPLWHDOYHQWLODGRUUHDOL]DUFLFORV
GHHQFHQGLGR\DSDJDGRFRQHOFRPSUHVRURHOFDOHIDFWRU
HOpFWULFR(OYHQWLODGRUVHGHWLHQHGXUDQWHXQSHUtRGRGH
WLHPSRFRUWRXQDYH]TXHODFRQILJXUDFLyQGHWHPSHUDWXUD
es satisfactoria.
Límites del Punto de Configuración de Temperatura
Brinda un rango restringido del control de temperatura.
Loading ...