1
SHUTTER MOUNTED EXHAUST FAN
background
2
Models: ILG8SF7V , ILG8SF10V
ILG8SF12V , ILG8SF16V
ILG8SF18V , ILG8SF18S
ILG8SF20V , ILG8SF24V
ILG8SF30S , ILG8SF36S
OWNER'S MANUAL
PLEASE READ AND SAVE THESE
INSTRUCTIONS
background
PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE
ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT
DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR
FUTURE REFERENCE.
BEFORE YOU BEGIN
WARNING!
of parts are to be performed only by authorized service technicians.
Electrical Requirements:
• The motor amperage and voltage ratings must be checked for
compatibility to supply voltage prior to final electrical connection. Please
refer to the motor's nameplate label.
• Wiring must conform to local, state, and national codes.
Tools / Materials N
eeded:
• Mounting Fasteners (8)
• Sealant or Caulk
• Regular Screwdriver Set
Recommended Accessories:
• Speed control for
ILG8SF
ILG8SF18V, ILG8SF20V
, ILG8SF24V
UNPACKING
Contents:
• Shutter Mounted
Exhaust Fan
• Owner’s Manual
PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE
ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR
Installation, troubleshooting, and replacement
of parts are to be performed only by authorized service technicians.
The motor amperage and voltage ratings must be checked for
compatibility to supply voltage prior to final electrical connection. Please
refer to the motor's nameplate label.
Wiring must conform to local, state, and national codes.
eeded:
Recommended Accessories:
ILG8SF
7V, ILG8SF10V, ILG8SF12V,
ILG8SF16V
, ILG8SF24V
Exhaust Fan
3
PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE
ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR
Installation, troubleshooting, and replacement
of parts are to be performed only by authorized service technicians.
The motor amperage and voltage ratings must be checked for
compatibility to supply voltage prior to final electrical connection. Please
ILG8SF16V
,
background
4
Inspect:
After unpacking fan, carefully inspect for any damage that may have
occurred during transit. Check for loose, missing, or damaged parts.
• Check all bolts, screws, set-screws, etc. for looseness that may have
occurred during transit. Tighten as needed. Rotate propeller by hand to
ensure it turns freely.
• See General Safety Instructions on page 3, and Cautions and Warnings
as shown.
Fans are UL/cUL Listed, Standard 705.
1. Do not depend on any switch as the sole means of disconnecting
power when installing or servicing the fan.
2. Always disconnect, lock-out, and tag-out power source before installing
or servicing. Failure to disconnect power source can result in fire, shock,
or serious injury.
3. Motor will restart without warning after thermal protector trips. Do not
touch operating motor; it may be hot enough to cause injury.
4. Do not place body parts or objects in fan or motor openings while motor
is connected to the power source.
5. All electrical connections should be made by a qualified electrician.
6. These utility exhaust fans are for general purpose exhaust applications
only. Do not use these exhaust fans in an area where corrosive or
explosive materials may be found.
7. Follow all local and state/provincial electrical and safety codes in the
United States and Canada, as well as the National Electrical Code (NEC)
GENERAL SAFETY INSTRUCTIONS
background
5
and the Occupational Safety and Health Act (OSHA) in the United States,
and the Canadian Electric Code (CEC) in Canada.
8. Always disconnect power source before working on or near a motor or its
connected load.
9. Protect the power cable from coming in contact with sharp objects.
10. Do not kink or create tight bends in the power cable and never allow the
cable to come in contact with oil, grease, hot surfaces, or chemicals.
11. Make certain that the power source conforms to the requirements of
your specific exhaust fan model. The fan frame and motor must be
electrically grounded to a suitable electrical ground, such as a grounded
water pipe or ground wire system.
12. To reduce the risk of injury to persons, please observe the following:
In the United States, OSHA compliant guards are required when fan is
installed within 7 feet of the floor or working level. In Canada, CSA
compliant guards are required when fan is installed below 2.5 meters
(8.2 feet) above the floor or grade level.
13. Questions? Please contact our service center by calling 1-800-317-
1688.
background
INSTALLATION INSTRUCTION
1. The unit should be securely mounted in a
NOTE:
Allowing the fan frame to flex or move will result in excess
vibrations, which may cause possible premature motor, propeller, or
shutter failure.
2. Install any auxiliary components such as thermostats, switches, or speed
controls.
3
. Connect power to the motor using an approved wiring method.
Refer to the following wiring diagrams
Fan frame and motor must be securely and adequately grounded
to a suitable electrical ground, such as a ground water pipe or
ground wiring system.
INSTALL
ATION
INSTALLATION INSTRUCTION
1. The unit should be securely mounted in a
rigid framework.
Allowing the fan frame to flex or move will result in excess
vibrations, which may cause possible premature motor, propeller, or
2. Install any auxiliary components such as thermostats, switches, or speed
. Connect power to the motor using an approved wiring method.
Refer to the following wiring diagrams
: Figure 1 & Figure 2.
Fan frame and motor must be securely and adequately grounded
to a suitable electrical ground, such as a ground water pipe or
ATION
INSTRUCTIONS
6
Allowing the fan frame to flex or move will result in excess
vibrations, which may cause possible premature motor, propeller, or
2. Install any auxiliary components such as thermostats, switches, or speed
. Connect power to the motor using an approved wiring method.
Fan frame and motor must be securely and adequately grounded
to a suitable electrical ground, such as a ground water pipe or
INSTRUCTIONS
background
7
Figure 1: Wiring Diagram - Speed Controllable. 115-volt connection.
for ILG8SF7V, ILG8SF10V, ILG8SF12V, ILG8SF16V,ILG8SF18V,
ILG8SF20V, ILG8SF24V
Figure 2: Wiring Diagram - Single speed. 115-volt connection.
for ILG8SF18S, ILG8SF30S, ILG8SF36S
GENERAL SPECIFICATIONS
background
8
Power source
115V, 60Hz
Mounting Position
Vertical
Frame Material
Galvanized Steel
Shutter Blade Material
Aluminum Alloy
Propeller Material
Aluminum Alloy and Galvanized Steel
Agency Compliance
UL/cUL 705
Dimensions (Inches)
MODEL
Prop.
Dia. A B C D E N G F O H J I
Suggested wall
opening (Sq)
Figure
3
background
9
Performance
MODEL
Prop.
Dia.
Nom.
HP Amps
Nom.
RPM
Bearing
Type
Sones @
0.0" SP @
5'
CFM Air Delivery @ Static
Pressure Shown
0.00" 0.125" 0.25"
ILG8SF
7
V
7" 1/25 0.40 1550 Sleeve 5.37 242 N/A N/A
ILG8SF10V
10" 1/25 0.55 1550 Sleeve 6.19 600 354 N/A
ILG8SF12V
12" 1/20 0.60 1625 Sleeve 5.9 772 418 N/A
ILG8SF16V
16" 1/20 0.85 1550 Ball 6.39 1200 416 180
ILG8SF18V
18" 1/15 0.85 1075 Ball 7.4 1736 1108 N/A
ILG8SF18S
18" 1/4 3.50 1725 Ball 7.28 3852 2836 2172
ILG8SF20V
20" 1/4 2.75 1075 Ball 6.67 3368 2312 1868
ILG8SF24V
24" 1/4 2.75 1075 Ball 7 4244 2676 2220
ILG8SF30S
30" 1/3 3.30 825 Ball 7.01 5088 3432 1552
ILG8SF36S
36" 1/2 6.00 825 Ball 8.24 6128 4380 2620
ILG8SF
7
V
7" 11" 11" 5 3/4" 2" 5 7/8" 9 21/32"
8 1/8" 8 1/8" 4 1/16" 3 17/32"
9/32"
1/2"
8 1/2"
ILG8SF10V
10" 13" 13" 4 17/32"
2" 5 7/8" 11 21/32"
10 1/8" 10 1/8" 6" 3 17/32"
9/32"
1/2"
10 1/2"
ILG8SF12V
12" 15" 15" 5 3/4" 2" 6 5/32" 13 5/8" 12 1/8" 12 1/8" 8" 3 1/2" 9/32"
1/2"
13"
ILG8SF16V)
16" 18 29/32"
18 29/32"
5 3/4" 2" 7 7/8" 17 3/4" 16" 16" 11 29/32"
3 17/32"
9/32"
1/2"
17"
ILG8SF18V 18" 21" 21" 5 3/4" 2" 8 3/4" 19 11/16"
18" 18" 14" 3 17/32"
9/32"
1/2"
19"
ILG8SF18S)
18" 21" 21" 5 3/4" 2" 10 13/16"
19 11/16"
18" 18" 14" 3 17/32"
9/32"
1/2"
19"
ILG8SF20V)
20" 23" 23" 5 3/4" 2" 11" 21 25/32"
20" 20" 16" 3 17/32"
9/32"
1/2"
21"
ILG8SF24V 24" 27" 27" 5 3/4" 2" 11" 25 21/32"
24 1/8" 24 1/8" 20 1/32" 3 17/32"
9/32"
1/2"
25"
ILG8SF30S 30" 33" 33" 5 3/4" 3" 13 3/32"
31 5/8" 30 1/8" 30 1/8" 26" 3 17/32"
9/32"
1/2"
31"
ILG8SF36S 36" 39" 39" 5 3/4" 3" 13 11/16"
37 21/32"
36 5/32"
36 5/32"
32" 3 17/32"
9/32"
1/2"
37"
background
1. Keep the area free of objects that could impede air flow on both the
intake and exhaust side of fan.
2. For proper exhaust operation, a
opened for fresh air intake on the opposite
ventilated.
3. Turn the fan ON; the shutter will open automatically. When the unit is
turned OFF, the shutter will close.
4. Speed controllable units are d
percent line voltage.
1. Disconnect power source before servicing.
2. Periodically clean off accumulated dirt from the propeller, guard, motor,
and shutter.
Do not depend on any switch as
OPERATING INSTRUCTIONS
MAINTAINANCE
1. Keep the area free of objects that could impede air flow on both the
intake and exhaust side of fan.
2. For proper exhaust operation, a
window, door, or louver should be
opened for fresh air intake on the opposite
side of the area to be
3. Turn the fan ON; the shutter will open automatically. When the unit is
turned OFF, the shutter will close.
4. Speed controllable units are d
esigned to operate at a minimum of fifty
1. Disconnect power source before servicing.
2. Periodically clean off accumulated dirt from the propeller, guard, motor,
Do not depend on any switch as
the sole means of
OPERATING INSTRUCTIONS
MAINTAINANCE
10
1. Keep the area free of objects that could impede air flow on both the
window, door, or louver should be
side of the area to be
3. Turn the fan ON; the shutter will open automatically. When the unit is
esigned to operate at a minimum of fifty
2. Periodically clean off accumulated dirt from the propeller, guard, motor,
background
disconnecting power when installing or servicing. If power disconnect
is not visible, utilize OSHA Lock out/Tag out procedure.
Failure to do so may result in fatal electrical shock.
Employ proper lock-
out/tag
maintenance.
Symptom
Possible Cause(s)
Excessive noise
Dry motor bearings
Loose propeller
Bent or damaged
propeller
Loose guard assembly or
motor fasteners.
Fan inoperative
Blown fuse or open
circuit breaker
Defective motor
Switch in OFF
Blocked intake or
exhaust opening
TROUBLESHOOTING
disconnecting power when installing or servicing. If power disconnect
is not visible, utilize OSHA Lock out/Tag out procedure.
Failure to do so may result in fatal electrical shock.
out/tag
-out procedures when perform
ing
Possible Cause(s)
Solution
Dry motor bearings
Re-
lubricate motor
bearings as per
instructions
or replace motor.
Loose propeller
Tighten set screws on
propeller hub.
Bent or damaged
propeller
Replace propeller
Loose guard assembly or
motor fasteners.
Tighten as required to 15
20 lbs. per inch.
Blown fuse or open
circuit breaker
Replace fuse or reset
circuit breaker
Defective motor
Replace motor
Switch in OFF
position Turn switch ON
Blocked intake or
exhaust opening
Clear intake and exhaust
openings of any
obstructions.
Clean motor, guard,
propeller, and
shutter
assembly. Increase the
opening of the fresh air
intake.
TROUBLESHOOTING
11
disconnecting power when installing or servicing. If power disconnect
ing
Solution
lubricate motor
instructions
or replace motor.
Tighten set screws on
Replace propeller
Tighten as required to 15
-
Replace fuse or reset
Clear intake and exhaust
Clean motor, guard,
shutter
assembly. Increase the
opening of the fresh air
background
12
Insufficient air
flow
Low voltage Check electrical wiring.
Speed control set too low Increase speed with
controller
iLIVING USA
239 Harbor Way
South San Francisco, CA 94080
Tel: 800-317-1688
Email: servic[email protected]
Like us on Facebook: https://www.facebook.com/ilivingusa/
Follow us on Twitter: @iLIVINGUSA
Check out our website: www.ilivingusa.com

Specifications

ILiving ILG8SF16V Questions and Answers

Questions and Answers

Related Products