US Stove Company 5520 2,200 Sq. Ft. Pellet Stove with 120 lb Hopper and Ash Pan

User Manual - Page 14

For 5520.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
-14-
OPTIONAL THERMOSTAT
A optional thermostat may help you maintain a constant
house temperature automatically. A millivolt thermostat is
required. A xed wall mount or hand held model can be
used. The control panel can be set up two ways to operate
your stove in thermostat mode.
THERMOSTAT INSTALLATION
A MILLIVOLT NON-PROGRAMMABLE THERMOSTAT IS
REQUIRED.
Unplug stove from power outlet.
Remove control board from stove.
The two thermostat wires connect to the terminal block
on the lower left side of the back of the control board.
Insert the wires in the terminal side and tighten the two
screws.
MODES
TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE
MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE
STOVE RESTARTED.
MANUAL MODE
USE THIS MODE EXCLUSIVELY IF YOU DO NOT CONNECT
AN OPTIONAL THERMOSTAT.
In this mode the stove will operate only from the control
panel as detailed in the “OPERATION” section of this
owner’s manual.
HIGH/LOW THERMOSTAT MODE
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT.
When engaged in this mode the stove will
automatically switch between two settings. When
warm enough, it will switch to the #1 or low setting. The
room air blower will also slow to its lowest speed.
The Heat Level Advance setting on the bar graph will
stay where it was initially set. When the house cools
below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.
ON/OFF THERMOSTAT MODE (IGNITOR LIFE WILL BE CUT DOWN IN THIS MODE)
USE THIS MODE ONLY IF YOU CONNECT A THERMOSTAT.
In this mode, when the home is warm enough the stove will shut off. The fans will continue to run until the
stove cools.
When the home cools below the thermostat setting, the stove will automatically restart and run at the last
feed rate setting.
NOTE: When in “high/low” or “on/off” thermostat mode –
Do not operate the stove higher than the #3 setting.
Set damper control rod approximately 1/4” to 1/2” out. This will vary depending on elevation and weather
conditions. Observe stoves operation and adjust damper as necessary.
Thermostat Installation
On/Off High/Low Manual