Page 4 of 8 Zip Domestic Chill Tap - Installation & Operating Instructions - 87403 - June 2007
# Domestic Installation Instructions continued
Use a 25 mm sheet metal punch to create a neat hole without burrs.
Remove the nut and washer from the base of the carafe filler, leaving the rubber-
sealing ring in place.
Fit the carafe filler and seal to the sink, oriented so that the operating lever is away
from the sink bowl.
Slide the washer and nut over the tubes from under the sink, and tighten the nut to
secure the carafe filler firmly into place.
Connecting
If this model comes with a filtration kit, follow the separate filter kit installation
instructions.
It this is an unfiltered model, only a 1/2" BSP to 1/4" tube adaptor is supplied.
You must separately supply and install an isolating valve in the supply line before
the connection to the product.
If the pressure exceeds 700kPa, you must also supply and install a 350kPa
pressure-limiting valve.
From the outlet of the pressure limiting valve or the outlet of the filter housing
(if supplied) connect the CLEAR tubing from the vented carafe filler, cut excess off
to ensure a neat job. Make sure all connections to John Guest fittings are pushed in
past the “O”ring to full depth, at least 15-16mm.
Now measure and cut the RED tube to connect directly to the JG fitting marked
INLET on the top right rear of the chiller unit. Insulate the BLUE tube with the loose
length of the pipe insulation, cut both pieces to correct length. Now connect the
BLUE tube to the JG fitting marked OUTLET on the top left rear of the chiller.
Tap connection is now complete.
Precautions
The plumbing installation must be done in accordance with local Water Authority
regulations and these Installation Instructions.
As the installer, it is your responsibility to supply (if necessary) and install all valves
as required by local regulations and relevant standards.
The chiller and filtration systems are indoor units and must not be exposed to the
elements of nature.