25INSTALLATION
5. Tighten
each supply
connection
another 2/3
turn with
pliers. DO
NOT bend,
kink, or
pinch water
inlet hoses.
6. Turn on the water and check for
leaks.
Tighten by hand until snug. Then
tighten each supply connection
another 2/3 turn with pliers. DO
NOT cross thread or over-tighten
these connections.
4. Connect the
HOT inlet
hose to the
HOT water
supply and
the COLD
inlet hose to
the COLD
water supply.
Tighten by
hand until snug.
Connecting the exhaust
1. Remove the two screws securing
the dryer front access panel to the
dryer cabinet. Lift the panel until the
tabs can be disengaged from the
cabinet, remove the panel and set
aside.
2. Connect the exhaust duct to the
outside exhaust system. Use of a 4”
(10.2 cm) clamp is recommended
to connect the dryer to the exhaust
vent system. Use metal foil tape to
seal all other joints.
3. Reinstall the dryer front access
panel.
Clamp
WARNING
ELECTRIC SHOCK HAZARD
Certain internal parts are intentionally
not grounded and may present a risk
of electrical shock if contacted during
installation. Do not contact the following
parts while the appliance is energized:
Pump
Drive Motor
Electronic control boards
Water valve
4. Carefully slide the laundry center to
its final position. Recheck for level
and rock corners for stability.
Connecting the drain
1. Form a “U” shape on the end of the
drain hose with the hose pointed
toward the drain.
2. Place the formed end in a laundry
tub or a standpipe and secure the drain
hose with the cable tie (provided in the
enclosure package) to the standpipe,
inlet hose, laundry tub, etc. so the hose
does not pull out from the force of the
water.