Rear flush exhaust requirements
The laundry center may be exhausted
four (4) ways with rear flush installation:
1. Straight back with articulating elbow
back.
2. Down with articulating elbow down.
3. Left with articulating elbow left.
4. Right with articulating elbow right.
PRE-INSTALLATION REQUIREMENTS
An exhaust hood positioned to line up
with the dryer exhaust can be installed
directly through the outside wall. To
exhaust to the side or down, add an 8
inch (20.3 cm) length of standard 4 inch
(102 mm) diameter duct and a 90° elbow.
To exhaust up, add an 11 inch (28 cm)
length of standard 4 inch (102 mm)
diameter duct and a 90° elbow. The unit
will be positioned about 4.5 inches (11.5
cm) away from the wall (flush to wall
exhausting may be done by going below
the dryer then sideways).
See also Clearance Requirements in this
instruction.
Manufactured or mobile
home installation
1. Installation MUST conform to current
Manufactured Home Construction &
Safety Standard, Title 24 CFR Part
3280 (formerly the Federal Standard
for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or
Standard CAN/CSA-Z240 MH.
2. Dryer MUST be exhausted outside
(outdoors, not beneath the mobile
home) using metal ducting that
will not support combustion. Metal
ducting must be 4 inches (10.16 cm)
in diameter with no obstructions.
Rigid metal duct is preferred. Exhaust
ducts must be securely fastened
to a noncombustible portion of the
mobile home structure.
3. If dryer is exhausted through the
floor and area beneath the mobile
home is enclosed, the exhaust
system MUST terminate outside
the enclosure with the termination
securely fastened to the mobile
home structure.
4. Refer to previous sections in this
guide for other important exhaust
venting system requirements.
5. When installing a gas dryer into a
mobile home, a provision must be
made for outside make up air. This
provision is to be not less than twice
the area of the dryer exhaust outlet.
6. Installer MUST anchor this laundry
center to the floor with approved
Mobile Home Installation Kit - P/N
137067200.
The exhaust system should be
inspected and cleaned a minimum of
every 18 months with normal usage.
The more the dryer is used, the more
often you should check the exhaust
system and vent hood for proper
operation.